English
Language : 

PAF600F28024 Datasheet, PDF (2/3 Pages) TDK Electronics – 200V to 400VDC Input Full brick DC-DC Converters
PAF-F280 Series
200V to 400VDC Input Full brick DC-DC Converters
‹ Output Voltages from 7.2V to 57V
‹ 450W to 600W Output Power
‹ Current Share
‹ Operation to 100°C Baseplate
‹ Wide Adjustable Output Range
Key Market Segments & Applications
Servers & Rail Systems
High End Computers
Custom Power Supplies
PAF Features and Benefits
Feature
‹ Wide Adjustment Range
‹ Parallel Pin
‹ High Efficiency - up to 91%
Benefit
‹ Reduces need for custom modules
‹ Modules can be connected together for higher current
‹ Reduced heat losses
Specifications
MODEL
ITEMS
Nominal Output Voltage
VDC
Output Current (Max) 450W A
600W
Max Output Power
450W W
600W
Efficiency (Typ)
%
Input Voltage Range
VDC
Output Voltage Accuracy
%
Output Voltage Adjustment
VDC
Max Ripple & Noise
mV
Max Line Regulation
mV
Max Load Regulation
mV
Temperature Coefficient
°C
Overcurrent Protection
%
Overvoltage Protection
%
Signals & Control
-
Baseplate Temperature
-
Humidity (non condensing)
-
Cooling
-
Isolation Voltage
-
Shock
-
Vibration
-
Safety Agency Approvals
-
Weight (Typ)
g
Size (WxHxD)
mm
Warranty
yr
PAF450F280-12
PAF450F280-24
PAF450F280-28 PAF450F280-48
PAF600F280-12
PAF600F280-24
PAF600F280-28 PAF600F280-48
12
24
28
48
38
19
16.5
9.5
50
25
21.5
12.5
456
456
462
456
600
600
602
600
89-90
91
91
91
200-400VDC
±1
7.2 - 14.4
14.4 - 28.8
16.8 - 33.6
28.8 - 57.6
120
240
280
480
48
56
56
96
48
56
56
96
0.02%/°C
105 - 140%
125 - 145%
Remote Sense, Remote On/Off, Parallel Pin, Inverter Good, 11-14V Auxiliary voltage
-40°C to +100°C Baseplate: (See derating chart)
5 - 95% RH Operating, 5 - 95% RH Non Operating
Conduction (See Installation Manual for heatsink selection)
Input to Baseplate: 2500VAC (20mA); Input to Output 3000VAC for 1 min.;
Output to Baseplate: 500VDC for 1 min
196.1m/s2
Non Operating, 10-55Hz (sweep for 1 min.)
Amplitude 0.825mm constant (Max 49 m/s2) X,Y,Z 1 hour each
UL60950-1, CSA60950-1, EN60950-1, CE LVD
200
2.4 x 0.5 x 4.6 (61 x 12.7 x 116.8) See outline drawing
2 years
Note: See Installation Manual for full details, test methods of parameters and application notes.