English
Language : 

EFM30 Datasheet, PDF (2/5 Pages) Astrodyne Corporation – 30W Ultraminiature Open Frame Switching Power Supplies
30W Ultraminiature Open Frame Switching Power Supplies
EFM30 series
INPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ:
90-264 VAC
47-63 Hz
30A@115V, 60A@230V Input *
OUTPUT SPECIFICATIONS
Input-Out Isolation (1 min max.)
Efficiency
Switching Frequency
Safety
3KVAC
See Selection Chart
65Khz, (fixed, typical)
UL60950-1, EN60950-1
Voltage and Current
See Selection Chart
Load Regulation *3
See Selection Chart
Line Regulation (LL-HL)
±1%, max. (Singles & Duals)
0.6 / ±0.2%, max. (Triples)
Cross Regulation
Duals:
±2%. max. (0308: ±2 / ±6%)
Triples:
±3% max.
Preset Accuracy (FL,120VAC) 1% (0308: ±2 / ±5%)
1 / ±5%
DC Voltage Adjust (typ)
±10% of FS (Primary)
Temperature Coefficient
±0.03%/°C (0-50°C, typ)
Ripple/Noise *1, 4
See Selection Chart
Over Voltage Protection
Latching Auto Recovery *
Current Limit (auto recover) >110% of FS, Power Limit
Short Circuit Protection
Latching Auto Recovery *
Hold Up Time
20 mS, typ
PHYSICAL SPECIFICATIONS
Size Singles:
Duals/Triples:
Construction
Weight
2.36” x 3.41” x 0.93”
2.36” x 3.94” x 0.93”
Open Frame
4.3oz (122g)
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature (Free Air)
Storage Temperature
Relative Humidity
EMC
-10 to +70°C with Derate
-25 to +71°C *
0 to + 95%, non-cond *
EN55022, class II
Notes:
1. All measurements should be made directly at the terminals of the
power supply
2. Minimum Load is NOT required for proper operation. However, auxil-
iary outputs should be reduced as a function of primary output minimum
load or load reugulation will be higher.
3. Load Regulation measured from 20% to full load. All other outputs at
nominal load.
4. Output noise measured directky at pins at nomimnal load with 0.1uF
and 10uF capacitors, pk-pk @ 20MHz bandwidth.
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458