EFE300M Datasheet, PDF (2/4 Pages) TDK Electronics – 300 Watts, medical (BF rated) AC-DC, digital power solution
ISOLATION
Input to Output
Input to Earth
Reinforced
Basic
4kV (ac), 5.7kV (dc) type tested to 4kVac (equivalent to 5.7kVdc), production tested to 4.3kVdc.
1.5kV (ac), 2.3 kV (dc)
Output to Earth
1500 V (ac)
OUTPUT SPECIFICATION
Output Power
Peak Power
Total Regulation
Ripple & Noise
Voltage Setting Range
Voltage Setting Accuracy
Turn on Time
Efficiency
Hold up
Min Load
Transient Response
Recovery
Short circuit protection
Over Temperature protection
Over Voltage Protection
Fan supply
300W
400W
better than 4%
1.5%
+10% / -5%
±1%
1.5s max
90%
16ms min
None
<5%
<1ms
Yes
Yes
Yes
12V / 1A
Continuous
for 10 seconds (300W RMS)
Including Line (for 90-264Vac input change), Load (for 0-100% load change) and
temperature (0-50°C)
pk-pk, using EIAJ test method & 20MHz bandwidth
To be specified at time of ordering (chosen in ‘Output Voltage’ part of product code)
at 50% load
at 90 Vac & 100% rated output power
typical. 87% typical if Standby Supply is fully loaded
at 90 Vac, 75% load
of set voltage for 50% load change
(in 50µs within the range 25 - 100% load)
for recovery to 2% of set voltage
Auto recovery after removal of short circuit
Primary - auto recovers, secondary - cycle power to restart
Latching, need to cycle ac to restart unit.
Available if ‘no fan’ is specified, otherwise used by PSU fan.
GLOBAL SIGNALS
Remote on/off
Enable - TTL logic level low (relative to Standby 0V) enables channel 1 and fan supply
Inhibit - TTL logic level low (relative to Standby 0V) inhibits channel 1 and fan supply
Standby Supply 5V / 2A or 12V / 1A, isolated supply, not affected by remote on/off.
Power Good
Logic high indicates ac supply is good and Ch1 is within regulation
ORing FET
Allows redundant connection of power supplies with no additional diodes required.
ENVIRONMENT
Temperature
Convection Rating
Derating
Low Temp Startup
Humidity
Shock
Vibration
Altitude
Pollution
0 to 50°C operational, -40°C to 85°C storage (max 12 months).
Full load, with 2m/s air blown from input to output (approximately 10CFM)
TBC
50 to 70°C derate each output by 2.5% per °C
-20°C
5 - 95% RH non condensing
±3 x 30g shocks in each plane, total 18 shocks
30g shock = 11ms (+/-0.5msec), half sine
Conforms to EN60068-2-27, EN60068-2-47, IEC68-2-27, IEC68-2-47, JIS C0041-1987.
Conforms to MIL-STD-810E/F, Method 514.4, Pro I, Cat 1,9
Single axis 10 - 500 Hz at 2g (sweep and endurance at resonance) in all 3 planes
Conforms to EN60068-2-6, IEC68-2-6
Conforms to MIL-STD-810E, Method 516.5, Pro I, IV, VI
-200 to 3000 metres operational (-200 to 5000m storage/transportation)
Degree 2, Material group IIIb
IMMUNITY  EN61000-6-2:2005
Electrostatic Discharge
Electromagnetic Field
Fast / Burst Transient
Surge Immunity
Conducted RF Immunity
Power Frequency Magnetic Field
Voltage Dips, Variations, Interruptions
Ring Wave
Voltage Fluctuations
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
EN61000-4-12
EN61000-4-14
Level 4
Level 3
Level 4
Level 3
Level 3
Level 4
Class 3
Level 3
Class 3
Air discharge 15kV
Contact discharge 8kV
Not applicable to open frame units
12V/m
tested to 4.4kV
Common mode - 2.2kV
Differential - 1.1kV
12V
30A/m
Criteria B for 5 sec interruption
Criteria B for 1 cycle interruption
Common mode - 2.2kV
Differential - 1.1kV
Criteria
A
A
A
A
A
A
A
A
A
2
EFE300M Series