English
Language : 

ZWS300BAF Datasheet, PDF (1/2 Pages) TDK Electronics – 300W Single Output, Convection Cooled Power Supplies
ZWS300BAF Series
300W Single Output, Convection Cooled Power Supplies
Features
u Universal Input (85 - 265VAC)
u Power Factor Corrected
u Convection cooling
u Five year warranty
u Less than 0.5mA earth leakage current
Key Market Segments & Applications
Specifications
Model
Input Voltage
Input Current
Inrush Current (1)(2)
Power Factor
Leakage Current
Temperature Coefficient
Overcurrent Protection (3)
Overvoltage Protection
Hold Up Time (Typ) (1)
Efficiency (1)
Remote On/Off
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
V
A
A
-
mA
%/°C
-
V
ms
%
-
°C
°C
%RH
-
-
Isolation Resistance
-
Vibration (non operating)
-
Shock
-
Safety Agency Certifications -
Conducted & Radiated EMI -
Immunity
-
Weight (Typ)
g
Size (WxHxD)
in (mm)
Warranty
yrs
ZWS300BAF
85-265VAC (47-63Hz), 120-370VDC
3.5 / 1.8
15 / 30
0.98 at 100VAC, 0.93 at 200VAC, Meets EN61000-3-2
0.5mA Max. Typically 0.2mA (100VAC), 0.4mA (230VAC)
<0.02%/°C
>116% of rated output current
24V: 28.8-33.6V, 36V: 41.4-48.6V, 48V: 55.2-64.8V
18ms at 100VAC input
88 / 91%
Optional, contact factory
-10°C to +70°C, derate linearly to 40% load from 45°C to 70°C
-30 to +75°C
Operating: 30 - 90%RH, Storage: 10 - 90%RH
Convection
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC
(20mA) for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour each
< 196.1 m/s2
UL60950-1, CSA60950-1, EN60950-1, EN50178 OV II, CE Mark
EN55011/EN55022-B, FCC Class B, VCCI-B
EN61000-4-2 (lvl2, 3), -3 (lvl 3), -4 (lvl 3), -5 (lvl 3, 4), -6 (lvl 3), -8 (lvl 4), -11; EN61000-6-2
540g
3.31 x 1.65 x 7.09” (84 x 42 x 180)
Five Years
Notes:
(1) 100 / 200VAC Input
(2) 25°C ambient (cold start)
(3) Avoid prolonged operartion in overload
1-800-526-2324 • www.us.tdk-lambda.com/lp/
116
Disclaimer: us.tdk-lambda.com/lp/legal.htm