ZWQ1305224 Datasheet, PDF (1/2 Pages) TDK Electronics – 80W to 170W Quad Output Power Supplies | |||
|
80W to 170W Quad Output Power Supplies
Features
u Universal Input (85 - 265VAC)
u Power Factor Corrected
u Floating Adjustable Fourth Output
u Low Proï¬le <1U High
Key Market Segments & Applications
ZWQ Series
Speciï¬cations
Model
Input Voltage
Input Current (1)
Inrush Current (1)
Power Factor
Temperature Coefï¬cient
Max Output Power (convection)
Max Output Power (forced air)
Overpower Protection (2)
Minimum Load
Output Voltage Accuracy
Efï¬ciency (Typ)
Hold Up Time (1)
Leakage Current
Remote On / Off
Oper Temp (convection cooled)
Oper Temp (forced air cooled)
Storage Temperature
Humidity (non condensing)
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (W x H x D)
Warranty
ZWQ80 ZWQ80 ZWQ80 ZWQ80 ZWQ130 ZWQ130 ZWQ130 ZWQ130
-5222
-5223 -5224
-5225
-5222 -5223 -5224
-5225
-
85-265VAC (47-63Hz), 120-370VDC
A
1.6 / 0.8
2.6 / 1.3
A
14/28
-
Meets EN61000-3-2
-
<0.02%/°C
W
80
130
W 104
88.7
104
104
170
149.6
170
170
W >109
>93
>109
>109
>173
>152
>173
>173
A
V1: 0.9A Conv, 1.4A Forced Air
V1: 1.5A Conv, 2.1A Forced Air
%
±5% for outputs V2 and V3
%
72
ms
20
-
0.75mA max, 0.2mA (Typ) at 100VAC / 0.44mA(Typ) at 230VAC
-
See installation manual (Not available with /A cover option)
°C
-10°C to 60°C, derate linearly to 50% load from 40°C to 60°C. (3)
°C
-10°C to 70°C, derate linearly to 50% load from 50°C to 70°C. (>30cfm airï¬ow)(3)
°C
-30° to +85°C
-
Operating: 30 - 90% RH; Non-operating 10-95% RH
- I/P~Grnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Grnd 500VAC (100mA) for 1 min.
-
>100M at 25°C & 70%RH, Output to Ground 500VDC
-
10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
-
< 196.1 m/s2
-
UL60950-1, CSA60950-1, EN60950-1, CE Mark, EN50178
-
EN55011, EN55022-B, FCC Class B, VCCI-B
-
EN61000-4-2,-3,-4,-5,-6,-8,-11
g
550
730
mm 93.5 x 35 x 210 (refer to outline drawing)
106 x 35 x 225 (refer to outline drawing)
yrs
One Year
(1) 100/200VAC
(2) Avoid prolong operation in overload
(3) /A version - additional derating, see installation manual
1-800-526-2324 ⢠www.us.tdk-lambda.com/lp/
111
Disclaimer: us.tdk-lambda.com/lp/legal.htm
|
▷ |