ZUP36-6U Datasheet, PDF (1/2 Pages) TDK Electronics – Zero up programmable power supplies | |||
|
Zero up programmable power supplies
Features
u Constant Voltage / Constant Current
u Last Setting Memory
u Digital Meters
u Built-in RS232 & RS485 Interface w/ GPIB optional
u Bench or Rack Mount
u Embedded Microprocessor Controller
u Voltage up to 120V, Current up to 132A
Key Market Segments & Applications
ZUP Series
Speciï¬cations
Model
Load Regulation
Line Regulation
Recovery Time (1)
Temperature Coefï¬cient
Temperature Drift(2)
Up programming response time
Down prog. resp. time (CV)
Down prog. resp. time (CV)
Load Regulation
Line Regulation
Temperature Coefï¬cient
Temperature Drift(2)
Prog Voltage resolution
Prog Voltage accuracy
Prog Current resolution
Prog Current accuracy
Overvoltage Shutdown
Thermal Protection
Display - Voltage
Display - Current
Display - Status
Remote On/Off
Output Good
Voltage & Current Programming
Remote Sense
Communication Interface
Series & Parallel Operation
AC Input Voltage range
Inrush Current (100/200VAC)(3)
Hold Up Time (Typ) at 100VAC
Power Factor Correction
Temperature Range
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration & Shock (non-op.)
Safety Agency Approvals
Conducted & Radiated EMI
Warranty
ZUP6
ZUP10
ZUP20
ZUP36
ZUP60
ZUP80 ZUP120
-
2mV + 0.005% over 0 - 100% load change
-
1mV + 0.005% over 85 - 132 or 170 - 265VAC line change
ms
1ms
0.5ms
0.2ms
-
30ppm/°C following 30 minute warm up
-
0.01% + 2mV change in output
ms
50 - 60ms
80ms
120ms
ms
50ms (70ms ZUP60-14)
ms 250ms
350ms
400ms
500ms
750ms
600ms
800ms
-
0.01% + 5mA on 200W and 400W models, 0.07% + 10mA on 800W models
-
0.01% + 2mA on 200W and 400W models, 0.01% + 5mA on 800W models
-
100ppm/°C from rated current after 30 minute warm up time
-
0.02% + 5mA, 200W and 400W models, 0.05% + 10mA 800W models
-
Better than 0.028% of rated voltage
mV .02%+5mV .02%+8mV .02%+12mV .02%+20mV .02%+35mV .02%+50mV .02%+70mV
-
Better than 0.03% of rated voltage
-
0.4% + 40mA
V
0 - 7.5
0 - 13
0 - 24
0 - 40
0 - 66
0 - 88
0 - 132
-
Over temperature protected
- 3 digits (6, 20, 36, 60, 80V models), 3.5 digits (10, 120V models). Accuracy 0.2% ± 2 digits
-
3 digits, (3.5 digits 132A model). Accuracy 0.5% ± 3 digits
-
CV / CC, Alarm, Foldback, Local/Remote, On/Off
-
TTL signal or dry contact relay
-
Open Collector
-
By either Voltage (0-4V) or Resistance (0-4k)
-
Up to 0.5V compensation per output cable
-
RS232 & RS485 standard, IEEE488 optional
-
Series: Up to two units; Parallel: Up to ï¬ve units in master-slave conï¬guration
VAC
85-265VAC (47-63Hz)
A
15/30A, 200W models, 15A, 400W models, 30A, 800W models
ms
20
-
Complies with EN61000-3 Class A (0.99 typ)
-
Operating: 0 - 50°C; Storage: -20 to +70°C
-
Operating: 30 - 90% RH, Storage 10 - 95%RH
-
Internal fan
-
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
-
>100M at 25°C & 70%RH
-
Vibration:10-55Hz(1 min.) 2G constant X, Y, Z, when correctly mounted; Shock: <20G
-
UL3111-1, EN61010-1, CE Mark
- EN55022-B conducted, A radiated, FCC Class B conducted, A radiated, VCCI-2 conducted, -1 radiated
yrs
Three Years
Notes: (1) Recovery to within +/-50mV after load change of 50-100% (2) Over 8 hour period following 30 minute warm up time
(3) 25°C ambient (cold start)
1-800-526-2324 ⢠www.us.tdk-lambda.com/lp/
152