English
Language : 

RFE1600 Datasheet, PDF (1/2 Pages) TDK Electronics – 1600W 1U Front End Power Supplies
1600W 1U Front End Power Supplies
Features
u 1U High
u Internal ORing FETs & Current Share
u High Efficiency
u I2C, PMBus Communication Option
Key Market Segments & Applications
RFE1600 Series
Specifications
Model
Input Voltage Range
VAC
Input Current (Max) 100/230VAC A
Inrush Current
A
Power Factor Correction
-
Temperature Coefficient
%/°C
Overcurrent Protection
%
Overvoltage Protection
%
Overtemperature Protection
-
Hold up time
ms
Leakage Current
mA
Remote Sense Compensation
-
Indicators
-
Remote On/Off
-
Parallel Operation
-
AC Fail Signal
-
DC Good Signal
-
Remote Adjust
-
I2C Interface
-
Auxiliary Output
-
Operating Temperature
°C
Storage Temperature
°C
Humidity (Non condensing)
%RH
Cooling
-
Withstand Voltage
-
Isolation Resistance
MΩ
Vibration (Basic transportation) -
Shock (Basic transportation)
G
Safety Agency Certifications
-
Conducted and Radiated EMI
-
Immunity
-
Size (W x H x D)
in
Weight
g
Warranty
yrs
RFE1600
85 - 265VAC, 47 - 63Hz. See model selector for power derating(2)
14.2 / 8.1A
<35A
Meets EN61000-3-2, PF > 0.98 at full load
<0.02%/°C
105 - 115% (Programmable)
110% (Tracking). Cycle AC to reset or utilize Remote On/Off(1)
Shutdown with automatic reset. Warning signal provided(1)
>10ms, 100/230VAC Input, 80% loading
< 0.75 / 1.5mA, 100 / 230VAC, 60Hz
RFE1600-12: 0.25V/wire, RFE1600-24: 0.5V/wire, RFE1600-48: 1.0V/wire
AC OK: Green LED, DC OK / Fail: Green / Red LED
Yes, inhibit & enable
Yes, single wire current share, 5% accuracy of max current, up to 10 units
Open Collector, ON when AC is within 85 - 270VAC
Open Collector, ON when output is above 85 to 95% of setpoint (tracking)
By either external 0 - 5V signal or 1k potentiometer(1)
Isolated from output, Add suffix /S, PMBus compatible(1)
11.2 - 12.5V, 0.5A, 240mV ripple and noise
-10 to +70°C, derate 2%/°C from 50 to 60°C, 2.5%/°C from 60 to 70°C
-30 to +85°C
Operating: 10 - 90%RH, Storage: 10 - 95%RH
Two variable speed internal fans, airflow exits across input/output connector
Input to Output 3kVAC, Input to Output 2kVAC, Output to Ground: RFE1600-12, -24V
500VAC, RFE1600-48 1.5kVAC
>100MΩ at 25°C & 70%RH, Output to Ground 500VDC
MIL-810F, method 514.5
30G
UL60950-1, EN60950-1 (2nd Edition), CE Mark
EN55022 & FCC part 15; Conducted class B, Radiated class A
IEC61000-4-2 (lv 2,3), -3 (lv 2), -4 (lv2), -5 (lv3,4), -6 (lv2), -8 (lv 4), -11
Power Supply: 3.35 x 1.61 x 12.6
1550
Three
Notes
(1) See installation manual for detailed specifications & test methods
(2). Derate linearly 1%/V from 100VAC to 85VAC input
1-800-526-2324 • www.us.tdk-lambda.com/lp/
120
Disclaimer: us.tdk-lambda.com/lp/legal.htm