English
Language : 

PXC-M10 Datasheet, PDF (1/2 Pages) TDK Electronics – 10W Medical & Industrial DC-DC Converters
10W Medical & Industrial DC-DC Converters
Features
 Industry Standard DIP-24 Package
 9-36V or 18-75VDC Input
 Medical & ITE Safety Certifications
 5kVAC Isolation (2xMOPPs)
 2uA Leakage Current
 Low Off-Load Power Draw
PXC-M10 Series
Key Market Segments & Applications
Specifications
Model
Max Output Power
Voltage Accuracy
Voltage Adjustment (T)
Minimum Load
Line Regulation
Load Regulation
Cross Regulation
Ripple and Noise
Start up time
Remote on/off
Temperature Coefficient
Operating Temperature (1)
Storage Temperature
Thermal Shock
Relative Humidity (non condensing)
Transient Response (25% step load change)
Overvoltage Protection
W
%
%
-
%
%
%
-
ms
-
%/°C
°C
°C
-
%RH
μs
V
Overcurrent and Short Circuit Protection
Input Surge Voltage (Maximum for 100ms)
Isolation Voltage
Isolation Resistance
Isolation Capacitance (max)
Typical Switching Frequency (Fixed)
MTBF (MIL-HDBK-217F)
Vibration
Conducted and Radiated Emissions
Immunity
Safety Agency Certifications
Size (L x W x H)
Weight
Warranty
%
V
V
Ω
pF
kHz
Hours
-
-
-
-
mm(”)
g
yrs
PXC-M10
PXC-M10W
10W
±1%
+/-10% (-10% +20% on 15V & 24V single output models) (see options table)
None
Single Output: ±0.2%, Dual Output: ±0.5%
Single Output: ±0.2%, Dual Output: ±1%
±5% (25-100% load)
See table
30ms
See options table
<±0.02%/°C
-40 to +105°C, derating necessary above 77°C
-55 to 125°C
MIL-STD-810F
5 to 95%RH
< 250μs recovery
Single Output: 3.3V: 3.7-5V, 5V: 5.6-7V, 12V: 13.5-16V, 15V: 18.3-22V, 24V: 29.1-34.5V
Dual Output: 5V: 5.6-7V, 12V: 13.5-18.2V, 15V: 17-22V
Typically at 150%, hiccup with self recovery
5V input: 16V, 24V input: 50V, 48V input: 100V
5,000VAC
109Ω minimum
17pF maximum
300kHz (±30kHz)
3,849,000
MIL-STD-810F
See Installation Diagrams
EN61000-4-2, -3, -4, -5, -6 Pref Criteria A
IEC/EN60601-1, ES60601-1, CE Mark
31.8 x 20.3 x 10.2mm (1.25 x 0.8 x 0.4”)
14g
Two Years
Notes:
See installation manual for full specifications and test measurements.
(1) Convection cooling. See installation manual for forced air ratings.
1-800-526-2324 • www.us.tdk-lambda.com/lp/
143