English
Language : 

PH-A280 Datasheet, PDF (1/2 Pages) TDK Electronics – 50-150W, 200 to 425VDC Input DC-DC Converters
PH-A280 Series
50-150W, 200 to 425VDC Input DC-DC Converters
Features
 200 - 425VDC Input
 Base-plate Cooled
 Full Power at 100°C base plate
 Quarter Brick Footprint
Key Market Segments & Applications
Specifications
Model
Nominal Output Voltage
Input Voltage Range
Input Current
Output Voltage Adjustment
Ripple & Noise (max) pk-pk
Line Regulation (max)
Load Regulation (max)
Overcurrent Protection
Overvoltage Protection (1)
Remote Sense
Remote On/Off
Operating Temperature
Storage Temperature
Temperature Coefficient
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration
Shock
Safety Agency Certifications
Weight (Typ)
Size (WxHxD)
Warranty
VDC 3.3V
5V
12V
15V
24V
28V
48V
VDC
200 - 425VDC
A
0.42 - 0.62A (model dependant)
VDC 2.97 - 3.96 4 - 6
9.6 - 13.2 12 - 16.5 19.2 - 26.4 22.4 - 30.8 38.4 - 52.8
mV
100
100
150
150
240
280
400
mV
10
10
24
30
48
56
96
mV
10
10
24
30
48
56
96
%1
02 - 150% (Constant current style)
% 130 - 200 125 - 150 115 - 145 115 - 145 115 - 145 115 - 145 115 - 145
-
Yes
-
Yes; Low = ON, Open = OFF
oC
-40oC to +100oC Base-plate, -40oC to +85oC Ambient
oC
-55oC to +100oC
%/oC
0.02%/oC
%RH
5 - 95% RH Operating and Non Operating
-
Conduction (See Installation Manual for heatsink selection)
VAC
Input to Base-plate: 2.5kVAC; Input to Output 3.0kVAC for I min.;
Output to Base-plate: 500VAC for 1 min
-
>100M at 25oC and 70%RH, Output to Base plate 500VDC
-
Non Operating, 10-55Hz (sweep for 1 min.)
Amplitude 0.825mm constant (Max 49 m/s2) X,Y,Z 1 hour each
196.1m/s2
-
UL60950-1, CSA60950-1, EN60950-1, CE Mark
g
55
in (mm)
1.46 x 0.5 x 2.30” (37.2 x 12.7 x 58.3)
-
5 Years
Note: See Installation Manual for full details, test methods of parameters and application notes
(1) Cycle input or remote on/off to reset
1-800-526-2324 • www.us.tdk-lambda.com/lp/
165
Disclaimer: us.tdk-lambda.com/lp/legal.htm