PH-A280 Datasheet, PDF (1/2 Pages) TDK Electronics – 50-150W, 200 to 425VDC Input DC-DC Converters | |||
|
PH-A280 Series
50-150W, 200 to 425VDC Input DC-DC Converters
Features
ïµ 200 - 425VDC Input
ïµ Base-plate Cooled
ïµ Full Power at 100°C base plate
ïµ Quarter Brick Footprint
Key Market Segments & Applications
Speciï¬cations
Model
Nominal Output Voltage
Input Voltage Range
Input Current
Output Voltage Adjustment
Ripple & Noise (max) pk-pk
Line Regulation (max)
Load Regulation (max)
Overcurrent Protection
Overvoltage Protection (1)
Remote Sense
Remote On/Off
Operating Temperature
Storage Temperature
Temperature Coefï¬cient
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration
Shock
Safety Agency Certiï¬cations
Weight (Typ)
Size (WxHxD)
Warranty
VDC 3.3V
5V
12V
15V
24V
28V
48V
VDC
200 - 425VDC
A
0.42 - 0.62A (model dependant)
VDC 2.97 - 3.96 4 - 6
9.6 - 13.2 12 - 16.5 19.2 - 26.4 22.4 - 30.8 38.4 - 52.8
mV
100
100
150
150
240
280
400
mV
10
10
24
30
48
56
96
mV
10
10
24
30
48
56
96
%1
02 - 150% (Constant current style)
% 130 - 200 125 - 150 115 - 145 115 - 145 115 - 145 115 - 145 115 - 145
-
Yes
-
Yes; Low = ON, Open = OFF
oC
-40oC to +100oC Base-plate, -40oC to +85oC Ambient
oC
-55oC to +100oC
%/oC
0.02%/oC
%RH
5 - 95% RH Operating and Non Operating
-
Conduction (See Installation Manual for heatsink selection)
VAC
Input to Base-plate: 2.5kVAC; Input to Output 3.0kVAC for I min.;
Output to Base-plate: 500VAC for 1 min
-
>100M at 25oC and 70%RH, Output to Base plate 500VDC
-
Non Operating, 10-55Hz (sweep for 1 min.)
Amplitude 0.825mm constant (Max 49 m/s2) X,Y,Z 1 hour each
196.1m/s2
-
UL60950-1, CSA60950-1, EN60950-1, CE Mark
g
55
in (mm)
1.46 x 0.5 x 2.30â (37.2 x 12.7 x 58.3)
-
5 Years
Note: See Installation Manual for full details, test methods of parameters and application notes
(1) Cycle input or remote on/off to reset
1-800-526-2324 ⢠www.us.tdk-lambda.com/lp/
165
Disclaimer: us.tdk-lambda.com/lp/legal.htm
|
▷ |