PFE-SA Datasheet, PDF (1/2 Pages) TDK Electronics – 300-1008W AC-DC Power Module
PFE-SA, PFE500-F & PFE1000-FA
300-1008W AC-DC Power Module
Features
 Low profile, small size
 100°C baseplate temperature
 High power density
 High Efficiency
 Suitable for conduction cooling
 Power Factor Corrected (PFC)
Key Market Segments & Applications
Specifications
Model
AC Input
VAC
Input Current (115 / 230VAC)
Model dependant
A
Inrush Current (115 / 230VAC) (1) A
Power Factor
-
Output Voltage Setpoint Accuracy -
Ripple and Noise
(1) -
Over Current Protection
%
Over Voltage Protection
-
Series Operation
-
Parallel Operation
-
Power On Signal (ENA)
-
Auxiliary Supply
-
Remote On/Off (Opto isolated)
-
Overtemperature Protection
-
Operating Baseplate Temp.
°C
Storage Temperature
°C
Humidity (non condensing)
-
Cooling
-
Withstand Voltage (1 min) (3) -
Isolation Resistance
-
Vibration (non operating)
-
Shock
-
Safety Certifications
-
Weight
g
Size (WxHxL)
mm
in
Warranty
yrs
PFE300SA
PFE700SA
PFE500F
PFE1000F*
PFE500SA
PFE1000FA
85 to 265VAC, 47-63Hz (up to 440Hz) (4)
3.2 / 1.6
6.8 / 3.4
13.6 / 6.6 (100/200VAC)
5.2 / 2.5
7.0 / 3.4
100/200VAC
10.6 / 5.2
23 / 46A peak
0.95 minimum, meets EN61000-3-2
±2%
±1V
±2%
±2%
1%
4V
1%
1%
105 - 140% (Automatic Recovery)
105 - 140%
Manual reset
125 - 145%
60 - 69.6V
125 - 145%
125 - 145%
Yes
No
Yes (Droop mode) Yes (Single wire)
Yes (Single wire)
Open collector (10mA sink current). Low (on) when output is present
None
None
10 - 14V, 20mA
10 - 14V, 20mA
None
None
High = On
High = On
Yes
-40 to +100°C (2)
-40 to +100°C
Operating: 20 - 95%RH, Non Operating: 10 - 95%RH
Conduction
Input to Output 3kVAC, Input to Baseplate 2.5kVAC, Output to Baseplate 1.5kVDC
Output to baseplate: 100M Ohm at 500VDC, 25°C ambient, 70%RH
10-55Hz (1 min sweep), constant amplitude 0.825mm (max 49m/s2), X, Y, Z 1 hour each
196.1m/s2
UL60950-1, CSA60950-1 (cUL), EN60950-1, CE mark (LVD)
500
200
250
300
420
61 x 12.7 x 116.8mm
70 x 12.7 x 122mm 100 x 13.4 x 160mm
2.4 x 0.5 x 4.6”
2.76 x 0.5 x 4.8”
3.94 x 0.53 x 6.3”
2 years
5 years
2 years
5 years
Notes: (Consult Installation Manual for detailed specifications, test methods and application notes)
* PFE1000-F models - Last time buy March 1, 2017, please use PFE1000FA models as a replacement
1)
External components are required, consult Application Notes
2)
PFE500SA-12, PFE500F-12: -40 to 85°C. See instruction manuals for derating curves
PFE1000F28, PFE1000FA, PFE1000F48 & PFE1000FA48: -40 to 85°C below 170VAC input voltage.
See instruction manuals for derating curves
3)
PFE500F, PFE1000F, PFE1000FA: 500VDC Output to baseplate
4)
Reduced PFC above 63Hz. Contact technical support for 440Hz operation.
1-800-526-2324 • www.us.tdk-lambda.com/lp/
114