Features
u 26mm height
u 3 year Warranty
u Peak Load capable
u Light weight
u Output 1 isolated from outputs 2 & 3
u No minimum load
Key Market Segments & Applications
Specifications
Model
Input Voltage Range
Input Current Typ
(1)
Inrush Current
(1)
Leakage Current (240VAC, 60Hz)
Max Output Power
Efficiency (Typ)
Hold Up Time
(1)
Output Voltage Adjustment (3)
Overcurrent Protection
Overvoltage Protection
Operating Temperature
Storage Temperature
Humidity (Non condensing)
Cooling
Withstand Voltage
Vibration (non operating)
Shock
Safety Agency Approvals
Immunity
Conducted EMI
Weight (Typ)
Size (WxHxL)
Warranty
MTW15-51212
MTW30-51212
MTW60-51212
MTW15-51515
MTW30-51515
MTW60-51515
V
85 - 265VAC (47 - 440Hz)
A
0.42 / 0.25
0.8 / 0.4
1.4 / 0.8
A
25 / 50
20 / 40
20 / 40
mA
0.75mA Max
W
16
30
60
17.5
33
62.5
%
71
76
76
ms
20 / 150
20 / 140
10 / 20
-
V1: 5 to 5.25V
V1: 5 to 5.2V
V1: 4.5 to 5.5V
-
Yes, automatic recovery. Hiccup style on MTW30 & 60
V
V1: Zener Clamp
V1: Zener Clamp
V1 & V2: Zener Clamp
-
-20°C start up. -10 to +60°C, derating linearily to 70% load above 50°C
-
-30 to +75°C
-
10 - 90%RH (Operating & storage) at 35°C
-
Convection
-
Input to ground 2kVAC, Input to output 3kVAC, Output to ground 500VAC
- 5 - 10Hz: 10mm amplitude, 10 - 200Hz: 2G (19.6m/s2)10m sweep time, 3 axis, 1 hour each
- Acceleration: 60G (588m/s2) Half sine wave, 6 - 16ms pulse duration, 3x each direction
-
UL60950-1, CSA C22.2 No 60950-1 (C-UL), EN60950-1
-
EN61000-4-2 (Lv 4), -3, -4 (Lv 3), -5 (Lv 4), -6 (Lv 3), -8 (Lv 4), -11
-
FCC-Class B, EN55011-B, EN55022-B
g
150
210
330
mm
50 x 26 x 127
65 x 26 x 140
83 x 26 x 185
yrs
Three Years
Notes:
(1) 100/240VAC
(2) Output V1 is isolated from outputs V2 & V3
(3) Option /V suffix
1-800-526-2324 • www.us.tdk-lambda.com/lp/