LS20024 Datasheet, PDF (1/2 Pages) TDK Electronics – Single Output 150 - 200W General Purpose Power Supplies | |||
|
LS200 Series
Single Output 150 - 200W General Purpose Power Supplies
Features
ïµ Very low cost
ïµ Small Size
ïµ Wide Range AC Input
ïµ Convection or Fan Cooled
ïµ Three year warranty
ïµ 1.6â high (For 1U racking)
Key Market Segments & Applications
Speciï¬cations
Model
AC Input Voltage (300VAC for 5s) VAC
Input Frequency
Hz
DC Input Voltage
VDC
Inrush Current (230VAC, cold start) A
Power Factor
-
Input Current (115/230VAC)
A
Temperature Coefï¬cient
-
Overcurrent Protection
-
Overvoltage Protection (2) V
Overtemperature Protection (2) -
Hold Up Time (115/230V input) ms
Leakage Current (230VAC 60Hz) mA
Remote Sense
-
Remote On/Off
-
LED Indicator
-
Operating Temperature
°C
Storage Temperature
°C
Operating Humidity
-
Storage Humidity
-
Cooling
-
Withstand Voltage
-
Isolation Resistance
-
Vibration (non operating)
-
Shock
-
Immunity
-
Safety Agency Approvals
-
Conducted & Radiated EMI
-
Weight (Typ)
g
Size (LxWxH)
in
Warranty
yrs
LS200 (Enclosed style with internal fan) LS200/L (U channel style - no internal fan)
85 - 264VAC
85 - 264VAC (3)
47 - 63Hz
120 - 373VDC
60
Meets EN61000-3-2, -3 (Typical PF 0.98/0.95)(1)
3.5 / 1.7 (typical)
<0.02%/°C (0 - 50°C)
>105% of nominal or peak. Constant current style
3.3V: 3.8 - 4.45V, 5V: 5.75 - 6.75V, 7.5V: 8.6 - 10.1V, 12V: 15.1 - 17.75V
15V: 17.25 - 20.25V, 24V: 30.25 - 35.5V, 36V: 41.4 - 48.6V, 48V: 60 - 69.6V
Yes
20ms
<1mA
Yes
On: 0 - 0.8V; Off: 3 - 12V
Green LED = On
Fan or forced air rating: -25 to +70°C. Derate linearly to 60% load from +50 to +70°C
-40 to +85°C
20 - 90% RH (non condensing)
10 - 95% RH (non condensing)
Internal Fan (air exhausts from fan end)
Convection or customer supplied airï¬ow
Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz: 19.6m/s2 constant sweep 1 min X, Y, Z for 1 hour
< 196.1 m/s2 (20G)
IEC61000-4-2, -3, -4, -5, -6, -8, -11
UL /CSA (cUL) /IEC 60950-1 (2nd Ed), CE Mark (Additionally evaluated to EN 60950-1)
EN55011/EN55022-B, FCC--B
700
600
7.8 x 3.9 x 1.61â
Three Years
Notes:
(1) 115 / 230VAC input
(2) Recycle AC to reset
(3) (Derate linearly to 65% load from 115VAC to 85VAC)
1-800-526-2324 ⢠www.us.tdk-lambda.com/lp/
73
Disclaimer: us.tdk-lambda.com/lp/legal.htm
|
▷ |