KMS-A Datasheet, PDF (1/2 Pages) TDK Electronics – 15-60W Medical AC-DC PCB-Mount Power Supplies | |||
|
KMS-A Series
15-60W Medical AC-DC PCB-Mount Power Supplies
Features
ïµ Medical Safety Certiï¬cations (4kVAC Input - Output)
ïµ Class II (No ground needed)
ïµ Wide Temperature Range (-40 to +80oC)
ïµ Low off-load Power Draw
ïµ Smaller size than KMS
ïµ High Efï¬ciency
Key Market Segments & Applications
Photo (KMS60A shown)
Speciï¬cations
Model
Input Voltage Range (1)
Inrush Current Limiting (115 / 230VAC) (2)
Input Current (115 / 230VAC)
Off-load Power Draw
Recommended External Fuse
Temperature Coefï¬cient
Voltage Set Accuracy
Minimum Load
Overcurrent Protection
Overvoltage Protection
Hold-up Time (115 / 230VAC)
Leakage Current (Touch)
Series or parallel operation
Operating Temperature (3)
Maximum Case Temperature
Storage Temperature
Humidity
Cooling
Withstand Voltage
Immunity
Altitude
Safety Agency Certiï¬cation
Conducted and Radiated EMI
Weight
Size (LxWxH)
Mounting & Case
MTBF
Warranty
-
A
mA
W
-
-
%
-
-
%
ms
mA
-
-
°C
-
%RH
-
VAC
-
m
-
-
g
in
(mm)
-
hrs
yrs
KMS15A
KMS30A
KMS60A
90-264VAC 47-440Hz* or 120-370VDC*
20 / 40A
30 / 60A
55 / 95A
385 / 250mA
650 / 400mA
1500 / 1000mA
<0.1W
<0.15W
<0.3W
3.15 A slow blow type
±0.05%/°C
±2%
None
Hiccup mode, automatic recovery
Yes, Zener diode clamp
15 / 56ms (typ)
>10ms
<0.1mA at 264VAC
Yes, see application note for details
-40°C to +85°C, derate linearly to 30% load from 50°C to 80°C
90°C (83°C <115VAC) 85°C (78°C <115VAC) 80°C (73°C <115VAC)
-40°C to +90°C
10% to 95% RH (non-condensing)
Convection
Input to output: 4kVAC, 2 x MOPPs
EN61000-4-2, -3, -4, -5, -6, -8, -11
5000m
UL/CSA/IEC/EN 60950-1, ANSI/AAMI ES60601-1, IEC/EN 60601-1 (2xMOPPs)
EN55011 Class B
59g
130g
280g
2.07 x 1.08 x 0.93â
2.52 x 1.77 x 0.93â
3.5 x 2.5 x 1.06â
52.5 x 27.5 x 23.5 mm 64.0 x 45.0 x 23.5 mm 89.0 x 63.5 x 27.0 mm
PC board mountable. Resin case (UL 94V-0)
200,000 to 400,000 hours, model dependant
3 years
(1) Derate linearly to 80% load below 110VAC (100VAC for KMS15A)
(2) Cold start, 25oC ambient
(3) Derate linearly to 80% load below -30oC
* Safety certiï¬ed for AC input, 47-63Hz only