English
Language : 

JW-50 Datasheet, PDF (1/3 Pages) TDK Electronics – SPECIFICATIONS
JWS 50
NEMIC-LAMBDA
SPECIFICATIONS
A157-01-01A
MODEL
JWS50 JWS50 JWS50 JWS50 JWS50 JWS50
ITEMS
-3
-5
-12
-15
-24
-48
1 Nominal Output Voltage
V 3.3
5
12
15
24
48
2 Maximum Output Current
A 10
10
4.3
3.5
2.2
1.1
3 Maximum Output Power
W 33
50
51.6
52.5
52.8
52.8
4 Efficiency (Typ)
(*1) % 65
74
76
77
79
79
5 Input Voltage Range
(*2) -
85 - 265VAC (47-63Hz) or 120 - 330VDC
6 Input Current (100/200VAC)(Typ) (*1) A 0.6/0.3
0.8/0.4
7 Inrush Current(Typ)
-
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
8 PFHC
-
Built to meet EN61000-3-2
9 Power Factor (100/200VAC)(Typ) (*1) -
0.99/0.95
10 Output Voltage Range
V 2.85-3.63 4.5-5.5 10.8-13.2 13.5-16.5 21.6-26.4 43.2-52.8
11 Maximum Ripple & Noise 0 ~ +60°C mV 120
120
150
150
150
200
(*3) -10 ~ 0°C mV 160
160
180
180
180
240
12 Maximum Line Regulation
(*4) mV 20
20
48
60
96
192
13 Maximum Load Regulation
(*5) mV 40
40
96
120
150
240
14 Temperature Coefficient
Less than 0.02%/°C
15 Over Current Protection
(*6) A 10.5 ~ 10.5 ~
4.5 ~
3.6 ~
2.3 ~
1.15 ~
16 Over Voltage Protection
(*7) - 3.79-4.95 5.75-6.75 13.8-16.2 17.3-20.3 27.6-32.4 55.2-64.8
17 Hold-up Time (Typ)
(*8) -
20ms
18 Leakage Current
(*9) - 0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
19 Remote Sensing
-
-
20 Parallel Operation
-
-
21 Series Operation
-
Possible
22 Operating Temperature
(*10) -
-10 ~+60°C ( -10 ~+50°C:100%,+60°C:60%)
23 Operating Humidity
-
30 ~ 90%RH (No dewdrop)
24 Storage Temperature
-
-30 ~ +85°C
25 Storage Humidity
-
10 ~ 95%RH (No dewdrop)
26 Cooling
-
Convection Cooling
27 Withstand Voltage
-
Input - FG : 2KVAC (20mA), Input - Output : 3KVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
28 Isolation Resistance
- More than 100Mohm at 25°C and 70%RH Output - FG... 500VDC
29 Vibration
-
At no operating, 10-55Hz (Sweep for 1min)
30 Shock (In package)
19.6m/s2 Constant, X,Y,Z 1hour each.
-
Less than 196.1m/s2
31 Safety
(*11) -
Approved by UL1950, CSA950, EN60950,VDE0160.
Built to meet DENTORI
32 Conducted Emission
-
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
33 Radiated Emission
-
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B.
34 Weight(Typ.)
g
350
35 Size (WxHxD)
mm
37 x 85 x 159 ( Refer to Outline Drawing )
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. At 100/200VAC, Ta=25°C and maximum output power.
*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
input voltage range will be 100-240VAC(50/60Hz).
*3. Measure with EIAJ RC-9131 probe, Bandwise of scope :100MHz.
*4. 85 - 265VAC , constant load.
*5. No load-Full load, constant input voltage.
*6. Constant current limit with automatic recovery.
*7. OVP circuit will shut down output, manual reset (Line recycle).
*8. At 100/200VAC nominal output voltage and maximum output current.
*9. Measured by the each measuring method of UL,CSA,EN and DENTORI(at 60Hz).
*10. Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A157-01-02_).
*11. As for DENTORI, built to meet at 100VAC.