English
Language : 

DT100 Datasheet, PDF (1/2 Pages) Extech Instruments Corporation. – Ultrasonic Distance Finder
DT100/150-C Series
100W to 150W AC-DC External Power Supplies
Features
u CEC, EISA1 & ErP Stage 2 Compliant
u Wide Range AC Input
u Power Factor Correction
u Low Profile & Lightweight
u 87% Avg. Active Efficiency
Key Market Segments & Applications
Specifications
Model
DT100PWxxx-C
DT150PWxxx-C
Input Voltage range
-
90 - 264VAC (47 - 63Hz)
Inrush Current
A
<60A at 230VAC input, 25°C ambient cold start
Input Current (Maximum)
A
2.5A
Power Factor
-
Typically 0.9 at full load (Meets EN61000-3-2)
Leakage Current
µA
<600uA at 264VAC 60Hz
Hold Up Time (Typ)
ms
16ms at 115VAC input
Temperature Coefficient
-
±0.05%/°C
Voltage Accuracy
%
±1%
Adjustment Range
-
None
Minimum Load
A
None
Total Regulation
-
+5% / -2%
Ripple & Noise
%
See model selector
Short Circuit Protection
-
Continuous - hiccup mode
Overvoltage Protection
V
110 - 130% of nominal (Cycle input power to reset)
Efficiency
%
≥87% Avg. Active Efficiency
Operating Temperature
°C
0 to +40°C
Storage Temperature
°C
-10 to +70°C
Humidity (non condensing)
-
20 - 90% RH
Cooling
-
Convection
Withstand Voltage
- Input to Ground 1.5kVAC, Input to Output 3kVAC for 1 min. (Output is connected to Ground internally)
Isolation Resistance
-
>20M at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating)
-
23.52m/s2 (10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
Shock
-
< 196.1 m/s2 (20G)
Safety Agency Approvals
-
UL60950-1, EN609501-1, IEC60950-1
California Energy Commission (CEC) -
Efficiency Mark V
EISA
-
Efficiency Mark V
Offload Power Consumption
-
< 0.5W
Conducted & Radiated EMI
-
EN55022-B, FCC Class B
Immunity
-
EN55024
Weight (Typ)
g
730g
780g
Size (WxLxH)
in
3.35 x 6.7 x 1.73”
Cable Length & Thickness
mm
1050mm; 12 to 24V Models: #14 AWG, 36 to 48V Models: #16 AWG
AC Input Connector
-
IEC 320-C14 (Accepts IEC 320-C13)
Output Connector
-
Kycon KPPx-4P or equivalent Pins 1 & 2: -Vout, Pins 3 & 4: +Vout
MTBF
-
140,000 hours, 100% load, 25°C ambient, MIL-HNBK
Warranty
yr
One Year
(1) EISA - Energy Independence and Security Act of 2007
1-800-526-2324 • www.us.tdk-lambda.com/lp/
45