English
Language : 

CUT75 Datasheet, PDF (1/2 Pages) TDK Electronics – Dual or Triple Output 75W Low Profi le Power Supplies
CUT75 Series
Dual or Triple Output 75W Low Profile Power Supplies
Features
 3 x 5 x 1.06” footprint
 Output 1 isolated from outputs 2 & 3
 No minimum loading
 Convection Cooled
 Three year warranty
Key Market Segments & Applications
Specifications
Model
AC Input Voltage (1)
Input Frequency
DC Input Voltage
Inrush Current (cold start)
Power Factor
Input Current (100 / 200VAC)
Temp. Coefficient (-20 to +70°C)
Overcurrent Protection
Overvoltage Protection (2)
Hold Up Time (115 / 230V input)
Leakage Current (265VAC 50Hz)
Operating Temperature (3)
Storage Temperature
Op. Humidity (non condensing)
Cooling
Withstand Voltage
VAC
Hz
VDC
A
-
A
-
-
V
ms
mA
-
-
-
-
-
Isolation Resistance
-
Vibration (non operating)
-
Shock
-
Immunity
-
Safety Agency Certifications
Conducted & Radiated EMI
Weight (Typ)
Size (WxLxH)
Warranty
-
-
g
in (mm)
-
CUT75-522
CUT75-5FF
85 - 265VAC
47 - 63Hz
120 - 370VDC (No safety certification)
18A at 100VAC, 36A at 200VAC
Meets EN61000-3-2
2/1
V1: <0.02%/°C, V2 & 3 <0.03%/°C
> 105%
V1: 5.7-7.0, V2: 13.8 - 18.8V
V1: 5.7-7.0, V2: 17.2 - 21.0V
20ms
<0.3mA
-20 to +70°C. Derate linearly to 60% load from +50 to +70°C
-30 to +85°C
5 - 95% RH
Convection
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC,
V1 to V2 / V3 500VAC for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz: 19.6m/s2 constant sweep 1 min X, Y, Z for 1 hour
< 196.1 m/s2 (20G)
IEC61000-4-2 (lv 3, 4), -3 (lv3), -4 (lv 4), -5 (lv3, 4),
-6 (lv 3), -8 (lv 4), -11
UL60950-1, CSA60950-1-07 (cTUVus), EN60950-1, CE Mark
EN55011/EN55022-B, FCC--B
210 (open frame version)
3 x 5 x 1.06” (76 x 127 x 27)
Three Years
(1) Derate linearly to 60% load from 100VAC to 85VAC input
(2) Cycle AC to reset
(3) See derating curves in installation manual for all mounting orientatons
1-800-526-2324 • www.us.tdk-lambda.com/lp/
129
Disclaimer: us.tdk-lambda.com/lp/legal.htm