CN-A24 Datasheet, PDF (1/2 Pages) TDK Electronics – 50 & 100W 14.4 to 36VDC Input DC-DC Converters | |||
|
CN-A24 Series
50 & 100W 14.4 to 36VDC Input DC-DC Converters
Features
ïµ 14.4 - 36VDC Input
ïµ IEC 61373 Shock and Vibration
ïµ Base-plate Cooled
ïµ Full Power at 100°C base plate
ïµ Small Size
ïµ Quarter Brick Footprint
ïµ Wide input range
Key Market Segments & Applications
Speciï¬cations
Model
Nominal Output Voltage
Input Voltage Range
Input Current
Output Voltage Adjustment
Ripple & Noise (max) pk-pk
Line Regulation (max)
Load Regulation (max)
Overcurrent Protection
Overvoltage Protection
Remote Sense
Remote On/Off
Operating Temperature
Storage Temperature
Temperature Coefï¬cient
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration
(1)
Shock
(1)
Safety Agency Certiï¬cations
Weight (Typ)
Size (WxHxD)
Warranty
VDC
5V
12V
24V
VDC
14.4 - 36VDC (40V transient for 3 seconds)
A
2.48 - 4.91A (model dependant)
VDC
4.5 - 6
10.8 - 13.2
21.6 - 26.4
mV
100
150
240
mV
20
48
96
mV
40
96
192
%
105 - 140%
%
125 - 145% (Cycle input or remote on/off to reset)
-
Yes
-
Yes; Low = ON, Open = OFF
°C
-40°C to +100°C Baseplate
°C
-40°C to +100°C
%/°C
0.02%/°C
%RH
5 - 95% RH Operating and Non Operating
-
Conduction (See Installation Manual for heatsink selection)
VAC Input to Base-plate: 2kVAC; Input to Output 3.0kVAC for I min.; Output to Base-plate: 500VAC for 1 min
-
>100M at 25C and 70%RH, Output to Base plate 500VDC
-
Non Operating, 10-55Hz (sweep for 1 min.)
Amplitude 0.825mm constant (Max 49 m/s2) X,Y,Z 1 hour each
IEC61373 - Category 1, Grade B
-
196.1m/s2, IEC61373 - Category 1, Grade B
-
UL60950-1, CSA60950-1, EN60950-1
g
70g
in(mm)
1.45 x 0.5 x 2.28â (36.8 x 12.7 x 57.9)
yrs
5 Years
Note: See Installation Manual for full details, test methods of parameters and application notes
(1) Compliant to EN50155 & IEC60571
1-800-526-2324 ⢠www.us.tdk-lambda.com/lp/
192
Disclaimer: us.tdk-lambda.com/lp/legal.htm
|
▷ |