Features
 14.4 - 36VDC Input
 IEC 61373 Shock and Vibration
 Base-plate Cooled
 Full Power at 100°C base plate
 Small Size
 Quarter Brick Footprint
 Wide input range
Key Market Segments & Applications
Specifications
Model
Nominal Output Voltage
Input Voltage Range
Input Current
Output Voltage Adjustment
Ripple & Noise (max) pk-pk
Line Regulation (max)
Load Regulation (max)
Overcurrent Protection
Overvoltage Protection
Remote Sense
Remote On/Off
Operating Temperature
Storage Temperature
Temperature Coefficient
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration
(1)
Shock
(1)
Safety Agency Certifications
Weight (Typ)
Size (WxHxD)
Warranty
VDC
5V
12V
24V
VDC
14.4 - 36VDC (40V transient for 3 seconds)
A
2.48 - 4.91A (model dependant)
VDC
4.5 - 6
10.8 - 13.2
21.6 - 26.4
mV
100
150
240
mV
20
48
96
mV
40
96
192
%
105 - 140%
%
125 - 145% (Cycle input or remote on/off to reset)
-
Yes
-
Yes; Low = ON, Open = OFF
°C
-40°C to +100°C Baseplate
°C
-40°C to +100°C
%/°C
0.02%/°C
%RH
5 - 95% RH Operating and Non Operating
-
Conduction (See Installation Manual for heatsink selection)
VAC Input to Base-plate: 2kVAC; Input to Output 3.0kVAC for I min.; Output to Base-plate: 500VAC for 1 min
-
>100M at 25C and 70%RH, Output to Base plate 500VDC
-
Non Operating, 10-55Hz (sweep for 1 min.)
Amplitude 0.825mm constant (Max 49 m/s2) X,Y,Z 1 hour each
IEC61373 - Category 1, Grade B
-
196.1m/s2, IEC61373 - Category 1, Grade B
-
UL60950-1, CSA60950-1, EN60950-1
g
70g
in(mm)
1.45 x 0.5 x 2.28” (36.8 x 12.7 x 57.9)
yrs
5 Years
Note: See Installation Manual for full details, test methods of parameters and application notes
(1) Compliant to EN50155 & IEC60571