English
Language : 

CN-A110 Datasheet, PDF (1/2 Pages) TDK Electronics – 30W to 200W 60 to 160VDC Input DC-DC Converters
CN-A110 Series
30W to 200W 60 to 160VDC Input DC-DC Converters
Features
u 60 - 160VDC Input
u IEC 61373 Shock and Vibration
u Base plate Cooled
u Full Power at 100°C base plate
u Parallel Operation (200W Only)
u Small Size
u Quarter / Half Brick Footprint
u Full Power from -40 to +100°C
u Parallel Function (CN200)
Key Market Segments & Applications
Specifications
Model
Nominal Output Voltage
Input Voltage Range
Input Current
Output Voltage Adjustment
Ripple & Noise (max) pk-pk
Line Regulation (max)
Load Regulation (max)
Overcurrent Protection
Overvoltage Protection
Remote Sense
Remote On/Off
Parallel Operation
Operating Temperature
Storage Temperature
Temperature Coefficient
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration
Shock
Safety Agency Certifications
Weight (Typ)
Size (WxHxD)
Warranty
VDC
VDC
A
VDC
mV
mV
mV
%
%
-
-
-
°C
°C
%/°C
%RH
-
VAC
-
-
-
-
g
in
yrs
5V
12V
15V
24V
60 - 160VDC
0.34 - 2.16A (model dependant)
4.5 - 6
10.8 - 13.2
13.5 - 16.5
21.6 - 26.4
100
150
150
240
20
48
60
96
40
96
120
192
105 - 140%
125 - 145% (Cycle input or remote on/off to reset)
Yes
Yes; Low = ON, Open = OFF
CN200A 12V, 15V & 24V only
-40°C to +100°C Baseplate
-40°C to +100°C
0.02%/°C
5 - 95% RH Operating and Non Operating
Conduction (See Installation Manual for heatsink selection)
Input to Baseplate: 1.5kVAC; Input to Output 3.0kVAC for I min.;
Output to Baseplate: 500VAC for 1 min
>100M at 25°C and 70%RH, Output to Base plate 500VDC
Non Operating, 10-55Hz (sweep for 1 min.) Amplitude 0.825mm
constant (Max 49 m/s2) X,Y,Z 1 hour each IEC61373 - Category 1, Grade B
196.1m/s2, IEC61373 - Category 1, Grade B
UL60950-1, CSA60950-1, EN60950-1, CE LVD
CN30A-100A: 70g, CN200A 150g
CN30A-100A: 1.45 x 0.5 x 2.28”, CN200A: 2.4 x 0.5 x 2.28”
5 Years
Note: See Installation Manual for full details, test methods of parameters and application notes
1-800-526-2324 • www.us.tdk-lambda.com/lp/
180
Disclaimer: us.tdk-lambda.com/lp/legal.htm