English
Language : 

CE-1005 Datasheet, PDF (1/4 Pages) TDK Electronics – CE Series 1.2 - 2.5A Point of Load Converters
• 3 to 5V or 9 to 26V Input
• Outputs 1V to 12V
• Surface Mount
• Low 4.2mm to 5.5mm Profile
• Non Isolated Output
CE Series
1.2 - 2.5A Point of Load
Converters
Key Market Segments & Applications
Telecommunications
Datacom
Instrumentation
CE Series Features and Benefits
Features
• Wide range output
• Constant switching frequency
• Five sided shielding
Benefits
• Reduces need for custom models
• Easier system filtering
• Reduced EMI
Specifications
ITEMS
MODELS
Nominal Output Voltage VDC
Input Voltage Range VDC
Input Current (max)
A
Ripple & Noise (typ) (pk - pk) mV
Total Regulation (max)
mV
Overload Protection (typ)
A
Remote On / Off (1)
-
Temperature (operating)
°C
Temperature (storage)
°C
Humidity (operating)
-
Humidity (storage)
-
Cooling
-
Vibration (non operating)
-
Shock
-
Weight (max)
g
Size
mm
Warranty
yrs
CE-1003
CE-1004
CE-1005
CE-1050
1.5 to 3.3
3.3 to 5.0
1 to 3.3
(2) 3.3 tp 12.6
6 - 16
3 - 5.25
9 - 26.4
2.4
1.8
100
50
±5%
±4%
±5%
2
3
3.5
ON = 2 - 6V; OFF= 0-0.6V
ON = <0.5V; OFF= >2V ON = 3 -6V; OFF= 0-0.3V
-40°C to +85°C (CE1003, 80% load above 70°C)
-20°C to +85°C
-40°C to +85°C
-20°C to +85°C
10 - 90% RH Non condensing @ max temp +38°C
Sealed packaging, see Technical Download
Convection or forced air
Frequency: 10-2000Hz, Sweep time: 4 minutes per cycle
Amplitude: 10G, 30 minutes each x, y, and z direction
Peak Acceleration: 100G, Duration: 6msec; three times each axis
1.8
1.7
3.7
18.3 x 12.3 x 4.2
21.3 x 16.4 x 5.5
1
Notes: (1) Pin 5
(2) Input / output voltage differential must be at least 4V.
CE Series
1