English
Language : 

CC15-2403SFP-E Datasheet, PDF (1/2 Pages) TDK Electronics – Ultra Compact, 15W to 30W Single Output DC-DC Converters
CC-P-E Series
Ultra Compact, 15W to 30W Single Output DC-DC Converters
Features
u Compact Footprint / Low Profile
u 24V & 48V Inputs
u 3.3V to 15V Outputs
u Five Sided Shielding (Cased Version)
u Input - Output Isolation
u Parallel Operation
u Through Hole or SMT Versions
u DC OK signal
u Sequencing pin
Key Market Segments & Applications
Specifications
Model
Nominal Output Voltage
DC Input
Efficiency
Initial set accuracy
Total Regulation limits
Output Adjustment
Temperature Coefficient
Preload
Output Ripple
Overcurrent Protection
Overvoltage protection
Remote On/Off (RC)
Alarm (ALM)
Sequencing (PO)
V
VDC
%
%
%
-
%/°C
A
mV
-
-
-
-
-
Cooling
-
Operating Temp. Range
°C
Storage Temperature
°C
Humidity (Non condensing)
%RH
Isolation Voltage (Cased version) VDC
Isolation Voltage (Uncased version) VDC
Isolation Resistance
-
Shock (Non operating)
-
Vibration (non operating)
-
Safety Certifications
-
Weight
g
Size (LxWxH) (Thru hole ver., w/ case) mm
Warranty
yrs
3.3V
5V
12V
15V
24V Nominal: 18-36V, 48V Nominal: 36-76V
89 to 92% model dependant
±1%
+5%, -3%
None
<0.02%/°C
None
50mV
150mV
> 103% of nominal rating
Operates at 115 - 145% of nominal voltage
Logic high (pull high to shutdown), referenced to -Vin
Low On Fail, referenced to -Vin. 20 units maximum
Connecting PO terminals on multiple power supplies ensures all simultaneously
start up (20 units maximum)
Convection
-40 to 85°C, see derating curves on website
-40 to 85°C
5 - 95%RH
1000VDC 1 min. Input-Output, Input-Chassis, Output-Chassis
1500VDC 1 min. Input-Output
>50M at 25°C and 70%RH, 500 VDC Input-Output, Input-Case, Output-Case
980m/s2 (100G), 6ms, 6 directions, 3 times
10-55-10 Hz (sweep for 15 min.) 1.52mm amplitude, 2 hour X, Y, Z
UL60950-1, CSA C22.2 No.60950-1 (c-UL), EN60950-1
With case: CC15 15g, CC30 20g. Without case: CC15 10g, CC30 15g
CC15: 38.4 x 6.8 x 29.6mm, CC30: 38.4 x 8.3 x 33.5mm
5 years
Note: See Installation Manual for full specifications, test methods of parameters and application notes
1-800-526-2324 • www.us.tdk-lambda.com/lp/
15