Register Set
The device is controlled and monitored by data registers and a command register accessed through the serial
interface. These registers provide for a variety of control functions and can be read to determine results of the
ADC conversions. The register set is summarized in Table 1.
ADDRESS
−−
0x00
0x01
0x03
0x04
0x05
0x06
0x07
0x0C
0x0D
0x0F
0x12
0x13
0x14
0x15
0x16
0x17
RESISTER NAME
COMMAND
ENABLE
ATIME
WTIME
AILTL
AILTH
AIHTL
AIHTH
PERS
CONFIG
CONTROL
ID
STATUS
C0DATA
C0DATAH
C1DATA
C1DATAH
Table 1. Register Address
R/W
REGISTER FUNCTION
W Specifies register address
R/W Enables states and interrupts
R/W ALS ADC time
R/W Wait time
R/W ALS interrupt low threshold low byte
R/W ALS interrupt low threshold high byte
R/W ALS interrupt high threshold low byte
R/W ALS interrupt high threshold high byte
R/W Interrupt persistence filters
R/W Configuration
R/W Control register
R Device ID
R Device status
R CH0 ADC low data register
R CH0 ADC high data register
R CH1 ADC low data register
R CH1 ADC high data register
RESET VALUE
0x00
0x00
0xFF
0xFF
0x00
0x00
0x00
0x00
0x00
0x00
0x00
ID
0x00
0x00
0x00
0x00
0x00
The mechanics of accessing a specific register depends on the specific protocol used. See the section on I2C
protocols on the previous pages. In general, the COMMAND register is written first to specify the specific
control/status register for following read/write operations.