PC29090100A Datasheet, PDF (4/11 Pages) List of Unclassifed Manufacturers – Cellular 850/900/1800/1900 & UMTS/WCDMA(3G) 2100 MHz 80mm*30mm PCB Antenna
4. Reliability
Test Items
Thermal Shock
Procedure
Starting at -40 for 30minutes and
then cycled to +85 to remain
30minutes (a complete cycle). To
repeat 5 complete cycles. (Refer to
IEC 68-2-14 Method Na)
Requirement
1. The value of return loss
must be within product
specifications after this test.
2. No physical deformation
should be evident.
Storage Temperature
(Cold)
Storage Temperature
(Dry Heat)
Samples must be put into -30°C
chamber for 72 hours and samples
shall be powered during test.
(Refer to IEC 68-2-1 Method Aa)
Samples must be put into +75°C
chamber for 72 hours and samples
shall be powered during test.
(Refer to IEC 68-2-1 Method Ba)
Operating Temperature
(Cold)
Samples must be put into -20°C
chamber for 2 hours and samples
shall be powered during test.
(Refer to IEC 68-2-1 Method Aa)
Operating Temperature
(Dry Heat)
Samples must be put into +65°C
chamber for 72 hours and samples
shall be powered during test.
(Refer to IEC 68-2-1 Method Ba)
1. The value of return loss must
be within product
specifications after this test.
2. No physical deformation
should be evident.
1. The value of return loss must
be within product
specifications after this test.
2. No physical deformation
should be evident.
1. The value of return loss must
met specification during
test/after test
2. No mechanical defects after
test.
1. The value of return loss must
met specification during
test/after test
2. No mechanical defects after
test.
SPE-11-8-045/E Page 4 of 11