AC1060 Datasheet, PDF (1/1 Pages) Nuvotem Talema – 60 Amp Current Transformer | |||
|
AC1060 ⢠60 Amp Current Transformer
Low Cost 50/60Hz Current Transformers
Applications
⢠Sensing Overload Current
⢠Ground fault detection
⢠Metering
⢠Analog to Digital Circuits
⢠Competitive pricing due to high volume
production
⢠Manufactured in an ISO-9001:2000,
TS-16949:2002 and ISO-14001:2004
certified Talema facility
⢠Fully RoHS compliant
Electrical Specifications @ 20°C ambient
Electrical Specifications
Primary Current
60A nom., 200A max.
Turns Ratio
1000:1 nominal
Volt per Amp Ratio at 60A for 100 ohm load
0.100 V/A
Volt per Amp Ratio at 6A for 100 ohm load
0.0984 V/A
DC Resistance at 20°C
24 ohms
Dielectric Withstanding Voltage (Hi-pot)
4KVrms
Mechanical Specifications
Case
Polycarbonate
Encapsulant
Epoxy
Flammibility
Conforms to UL94-VO
Terminals
Pins à 1.0mm
Marking
TALEMA
Date Code (W/Y)
AC1060, Dot at start pin
Approximate Weight
65.2 grams
Tolerance
±0.2mm
Environmental Specifications
Storage Temperature
-55° to +130°C
Insulation Resistance
100 megohms min.
10000
%RE vs RL at Rated primary current
(AC1060)
1000
Output Volts vs Input Current
For various ohmic loads
100
100
10K
5K
Infinity
2K
1K
10
500
200
100
1
50
10
-200
100
0
200
400
600
800
1000 1200
Percent ratio error in %
Typical Excitation Curve
(AC1060~AC1075)
10
0.1
10
Input Current in Amps
100
1
38.10
Dimensions
15.90
231
33.00
Ã14.60
2.85
10.16
TALEMA INDIA
W/Y
AC1060
5±1mm
à 1.016
0.1
0.01
0.1
1
10
Sec RMS Exciting Current in mA
Notes:
1) Unless requested, the terminating resistor and the one-turn
primary are not supplied
2) Pin 3: Normally for mechanical support only but will be
used on center tapped designs
I - Turn
Primary 60A
1
3
60mA
2
RL 1/2W
6.0V
100 ohms
Germany: Int.+49 89 - 841 00-0 ⢠Ireland: Int.+35 374 - 954 8666 ⢠Czech Rep: Int.+420 377 - 338 351 ⢠India: Int.+91 427 - 244 1325
http://www.talema-nuvotem.com
(06-06)CTâs\AC1060
|