|
JMK325BJ226MM-T Datasheet, PDF (43/48 Pages) Taiyo Yuden (U.S.A.), Inc – Notice for TAIYO YUDEN products | |||
|
◁ |
14. Humidity ï¼Steady stateï¼
Specified Value
Appearance
Capacitance change
Dissipation factor
Insulation resistance
: No abnormality
: Within±15%
: 7%maxï¼HMKï¼, 5%maxï¼QMK, SMKï¼.
: 25MΩμF or 1000MΩ, whichever is smaller.
Test Methods and
Remarks
Preconditioning
Temperature
Humidity
Duration
Recovery
: Thermal treatmentï¼at 150â for 1hrï¼ Note1
: 40±2â
: 90 to 95%RH
: 500 ï¼24/ï¼0 hrs
: 24±2hrs under the standard condition Note3
15. Humidity Loading
Specified Value
Appearance
Capacitance change
Dissipation factor
Insulation resistance
: No abnormality
: Within±15%
: 7%maxï¼HMKï¼, 5%maxï¼QMK, SMKï¼.
: 10MΩμF or 500MΩ, whichever is smaller.
Test Methods and
Remarks
According to JIS 5102 clause 9.9.
Preconditioning
: Voltage treatment Note2
Temperature
: 40±2â
Humidity
: 90 to 95%RH
Applied voltage
: Rated voltage
Charge/discharge current : 50mA max.
Duration
: 500 ï¼24/ï¼0 hrs
Recovery
: 24±2hrs under the standard condition Note3
16. High Temperature Loading
Specified Value
Appearance
Capacitance change
Dissipation factor
Insulation resistance
: No abnormality
: Within±15%
: 7%maxï¼HMKï¼, 5%maxï¼QMK, SMKï¼.
: 50MΩμF or 1000MΩ, whichever is smaller.
Test Methods and
Remarks
According to JIS 5102 clause 9.10.
Preconditioning
: Voltage treatment Note2
Temperature
: Maximum operating temperature
Applied voltage
: Rated voltageÃ2ï¼HMKï¼
Rated voltageÃ1.5ï¼QMKï¼
Rated voltageÃ1.2ï¼SMKï¼
Charge/discharge current : 50mA max.
Duration
: 1000 ï¼24/ï¼0 hrs
Recovery
: 24±2hrs under the standard condition Note3
Note1 Thermal treatment : Initial value shall be measured after test sample is heat-treated at 150ï¼0/ï¼10â for an hour and kept at room temperature for
24±2hours.
Note2 Voltage treatment : Initial value shall be measured after test sample is voltage-treated for an hour at both the temperature and voltage specified in the
test conditions, and kept at room temperature for 24±2hours.
Note3 Standard condition : Temperature: 5 to 35â, Relative humidity: 45 to 85 % RH, Air pressure: 86 to 106kPa
When there are questions concerning measurement results, in order to provide correlation data, the test shall be conducted
under the following condition.
Temperature: 20±2â, Relative humidity: 60 to 70 % RH, Air pressure: 86 to 106kPa
Unless otherwise specified, all the tests are conducted under the "standard condition".
ⶠThis catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
c_mlcc_mhv_reli_e-E02R01
|
▷ |