BK1608HS121-T Datasheet, PDF (22/27 Pages) Taiyo Yuden (U.S.A.), Inc – MULTILAYER CHIP BEAD INDUCTORS (BK SERIES) | |||
|
◁ |
â RELIABILITY DATA
Multilayer chip inductors and beads
15. Loading under Damp Heat
BK0402
BK0603
BK1005
BKH1005
BK1608
BK2125
BK2010
ARRAY
BK3216
Appearanceï¼No signiï¬cant abnormality.
Impedance changeï¼Within ±30ï¼
BKP0603
BKP1005
BKP1608
BKP2125
CK1608
CK2125
No mechanical damage.
Inductance changeï¼Within ±20ï¼
ãQ changeï¼Within ±30ï¼
CKS2125
No mechanical damage.ãInductance changeï¼Within ±20ï¼
CKP2012
CKP2016
CKP2520
No mechanical damage.ãInductance changeï¼Within ±30ï¼
NM2012
NM2520
LK1005
No mechanical damage.ãInductance changeï¼Within ±10ï¼
ãQ changeï¼Within ±30ï¼
LK1608
No mechanical damage.
Inductance changeï¼0.047 to 12.0μHï¼Within ±10ï¼
ã15.0 to 33.0μHï¼Within ±15ï¼
ãQ changeï¼Within ±30ï¼
LK2125
No mechanical damage.ãInductance changeï¼Within ±20ï¼
ãQ changeï¼Within ±30ï¼
HK0402
HK0603
HK1005
HK1608
HK2125
No mechanical damage.
Inductance changeï¼Within ±10ï¼
ãQ changeï¼Within ±20ï¼
HKQ0603S
HKQ0603U
AQ105
ãTest Methods and Remarksã
BK, BKP, BKH Seriesï¼
Temperatureï¼40±2â
Humidityï¼90 to 95ï¼
RH
Applied currentï¼Rated current
Durationï¼500ï¼ï¼204 hrs
Recoveryï¼2 to 3 hrs of recovery under the standard condition after the removal from test chambeï¼r. See Note 1ï¼
LKãCKãCKSãCKPãNMãHKãHKQãAQ Seriesï¼
Temperatureï¼40±2âï¼LKãCKãCKSãCKPãNM Seriesï¼
ï¼60±2âï¼HKãHKQãAQ Seriesï¼
Humidityï¼90 to 95ï¼
RH
Applied currentï¼Rated current
Durationï¼500±12 hrs
Recoveryï¼2 to 3 hrs of recovery under the standard condition after the removal from test chambeï¼r. See Note 1ï¼
Note on standard condition: "standard condition" referred to herein is deï¬ned as follows:
5 to 35â of temperature, 45 to 85% relative humidity, and 86 to 106kPa of air pressure.
When there are questions concerning measurement results:
In order to provide correlation data, the test shall be conducted under condition of 20±2â of temperature, 60 to 70% relative humidity, and 86 to 106kPa of air pressure.
Unless otherwise speciï¬ed, all the tests are conducted under the "standard condition."
(Note 1) Measurement shall be made after 48±2 hrs of recovery under the standard condition.
ï¼ This catalog contains the typical speciï¬cation only due to the limitation of space. When you consider the purchase of our products, please check our speciï¬cation.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
mlci0109_reli-PRP11
mlci0109_reli_e-01
|
▷ |