BK1608HS121-T Datasheet, PDF (22/27 Pages) Taiyo Yuden (U.S.A.), Inc – MULTILAYER CHIP BEAD INDUCTORS (BK SERIES)
■ RELIABILITY DATA
Multilayer chip inductors and beads
15. Loading under Damp Heat
BK0402
BK0603
BK1005
BKH1005
BK1608
BK2125
BK2010
ARRAY
BK3216
Appearance:No significant abnormality.
Impedance change:Within ±30%
BKP0603
BKP1005
BKP1608
BKP2125
CK1608
CK2125
No mechanical damage.
Inductance change:Within ±20% Q change:Within ±30%
CKS2125
No mechanical damage. Inductance change:Within ±20%
CKP2012
CKP2016
CKP2520
No mechanical damage. Inductance change:Within ±30%
NM2012
NM2520
LK1005
No mechanical damage. Inductance change:Within ±10% Q change:Within ±30%
LK1608
No mechanical damage.
Inductance change:0.047 to 12.0μH:Within ±10% 15.0 to 33.0μH:Within ±15% Q change:Within ±30%
LK2125
No mechanical damage. Inductance change:Within ±20% Q change:Within ±30%
HK0402
HK0603
HK1005
HK1608
HK2125
No mechanical damage.
Inductance change:Within ±10% Q change:Within ±20%
HKQ0603S
HKQ0603U
AQ105
【Test Methods and Remarks】
BK, BKP, BKH Series:
Temperature:40±2℃
Humidity:90 to 95%RH
Applied current:Rated current
Duration:500+-204 hrs
Recovery:2 to 3 hrs of recovery under the standard condition after the removal from test chambe(r. See Note 1)
LK、CK、CKS、CKP、NM、HK、HKQ、AQ Series:
Temperature:40±2℃(LK、CK、CKS、CKP、NM Series)
:60±2℃(HK、HKQ、AQ Series)
Humidity:90 to 95%RH
Applied current:Rated current
Duration:500±12 hrs
Recovery:2 to 3 hrs of recovery under the standard condition after the removal from test chambe(r. See Note 1)
Note on standard condition: "standard condition" referred to herein is defined as follows:
5 to 35℃ of temperature, 45 to 85% relative humidity, and 86 to 106kPa of air pressure.
When there are questions concerning measurement results:
In order to provide correlation data, the test shall be conducted under condition of 20±2℃ of temperature, 60 to 70% relative humidity, and 86 to 106kPa of air pressure.
Unless otherwise specified, all the tests are conducted under the "standard condition."
(Note 1) Measurement shall be made after 48±2 hrs of recovery under the standard condition.
* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.