English
Language : 

UMK105CG8R2DV-F Datasheet, PDF (11/17 Pages) Taiyo Yuden (U.S.A.), Inc – STANDARD MULTILAYER CERAMIC CAPACITORS
RELIABILITY DATA
3/3
Multilayer Ceramic Capacitor Chips
Specified Value
Item
Temperature CompensatingʢClass 1ʣ
High PermittivityʢClass 2ʣ
Test Methods and Remarks
Standard
High Frequency Type
Standard Note1
High Value
16.Loading under Damp Heat Appearance: No ab- Appearance: No ab- Appearance: No ab- Appearance: No ab- According to JIS C 5102 Clause 9. 9.
normality
normality
normality
normality
Multilayer:
Capacitance change: Capacitance change: Capacitance change: Capacitance change: Preconditioning: Voltage treatmentʢClass 2ʣ
Within ʶ 7.5% or ʶ Cʽ2 pF: Within ʶ0.4 pF BJ: Within ʶ12.5% BJɿWithinʶ12.5ˋ Temperature: 40ʶ2ˆ
4
0.75pF, whichever is
larger.
Q: Cʾ30 pF: Qʾ200
Cʻ30 pF: Qʾ100 ʴ
Cʼ2 pF: Within ʶ0.75
pF
C É¿ Nominal capaci-
tance
F: Within ʶ30%
Note 4
tan Ў: BJ: 5.0% max.
F: 7.5% max.
FɿWithinʶ30ˋ
Note 4
tanЎɿ
BJɿ5.0ˋmax.
Humidity: 90 to 95% RH
Duration: 500 ʴ ʵ024hrs
Applied voltage: Rated voltage
Charge and discharge current: 50mA max.Ê¢Class 1,2Ê£
10C/3
Insulation resistance:
Note 4
C ɿ Nominal capaci- 500 MЊ min.
Insulation resistance:
Fɿ11ˋmax.
Recovery: Recovery for the following period under the standard
Note 4
condition after the removal from test chamber.
tance
Insulation resistance:
25 MЊЖF or 500 MЊ, Insulation resistance:
whichever is the smaller. 25 MЊЖF or 500 MЊ,
6ʙ24 hrsʢClass 1ʣ
24ʶ2 hrsʢClass 2ʣ
500 MЊ min.
Note 5 whichever is the smaller. HighʔFrequency Multilayer:
Note 5 Temperature: 60ʶ2ˆ
Humidity: 90 to 95% RH
Duration:
500
Ê´24
ʵ0
hrs
Applied voltage: Rated voltage
Charge and discharge current: 50mA max.
Recovery: 6ʙ24 hrs of recovery under the standard
condition after the removal from test chamber.
17.Loading at High Tempera-
ture
Appearance: No ab-
normality
Capacitance change:
Within ʶ3% or
ʶ0.3pF, whichever is
larger.
Q: Cʾ30 pF : Qʾ350
10ʽCʻ30 pF: Qʾ275
Ê´ 2.5C
Cʻ10 pF: Qʾ200 ʴ
10C
CÉ¿ Nominal
capacitance
Insulation resistance:
1000 MЊ min.
Appearance: No ab-
Appearance: No abnormality
normality
Appearance: No ab- Capacitance change:
Capacitance change: normality
BJɿWithinʶ12.5ˋ
Within ʶ3% or ʶ
Capacitance change:
Withinʶ20ˋ˞˞
0.3pF, whichever is
BJ: Within ʶ12.5%
Withinʶ25ˋ˞˞
larger.
F: Within ʶ30%
FɿWithinʶ30ˋ
Insulation resistance:
Note 4
Note 4
1000 MЊ min.
tan Ў:
tanЎɿ
BJ: 4.0% max.
BJɿ5.0ˋmax.
F: 7.5% max.
Fɿ11ˋmax.ɹ
Note 4
Note 4
Insulation resistance: Insulation resistance:
50 MЊЖF or 1000 MЊ, 50 MЊЖF or 1000 MЊ,
whichever is smaller. whichever is smaller.
Note 5 Note 5
According to JIS C 5102 clause 9.10.
Multilayer:
Preconditioning: Voltage treatmentʢClass 2ʣ
Temperature:125ʶ3ˆʢClass 1, Class 2: B, BJʢX7Rʣʣ
85ʶ2ˆʢClass 2: BJ,Fʣ
Duration: 1000ʵʴ048hrs
Applied voltage: Rated voltageÊ·2 Note 6
Recovery: Recovery for the following period under the
standard condition after the removal from test chamber.
ɹɹɹ6ʙ24 hrsʢClass 1ʣ
ɹɹɹ 24ʶ2 hrsʢClass 2ʣ
HighʔFrequency Multilayer:
Temperature: 125ʶ3ˆʢClass 1ʣ
Duration: 1000ʴ ʵ048 hrs
Applied voltage: Rated voltageÊ·2
Recovery: 6ʙ24 hrs of recovery under the standard
condition after the removal from test chamber.
Note 1 :For 105 type, specified in "High value".
Note 2 :Thermal treatmentʢMultilayerʣ: 1 hr of thermal treatment at 150 ʴ0 /ʵ10 ˆ followed by 24ʶ2 hrs of recovery under the standard condition shall be performed before the measurement.
Note 3 :Voltage treatmentʢMultilayerʣ: 1 hr of voltage treatment under the specified temperature and voltage for testing followed by 24ʶ2 hrs of recovery under the standard condition shall be performed before the measurement.
Note 4, 5 :The figure indicates typical inspection. Please refer to individual specifications.
Note 6 :Some of the parts are applicable in rated voltageʷ1.5. Please refer to individual specifications.
Note on standard condition: "standard condition" referred to herein is defined as follows: 5 to 35ˆ of temperature, 45 to 85% relative humidity, and 86 to 106kPa of air pressure.
When there are questions concerning measurement results: In order to provide correlation data, the test shall be conducted under condition of 20ʶ2ˆ of temperature, 60 to 70% relative
humidity, and 86 to 106kPa of air pressure. Unless otherwise specified, all the tests are conducted under the "standard condition."
˚ʂ ౰ࣾΧλϩάΛ͝࢖༻ͷࡍʹ͸ʮ౰ࣾ੡඼ʹؔ͢Δ͓அΓʯΛඞ͓ͣಡΈ͍ͩ͘͞ɻ
˚ʂ Please read the "Notice for TAIYO YUDEN products" before using this catalog.
107