English
Language : 

PQ60033SMX15 Datasheet, PDF (6/15 Pages) SynQor Worldwide Headquarters – Output current limit and short circuit protection
Technical Specification
Input: 48V
Output: 3.3V
Current: 15A
PQ60033SMx15 Standards & Qualification Testing
Parameter
STANDARDS COMPLIANCE
UL 60950-1:2003
CAN/CSA-C22.2 No. 60950-1:2003
EN60950-1:2001
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
Notes & Conditions
Basic Insulation
Test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or
download from the SynQor website.
Parameter
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
# Units Test Conditions
32
5
5
10
5
5
5
15 pins
95% rated Vin and load, units at derating point, 1000 hours
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day
MIL-STD-883, method 2003
Product # PQ60033SMx15
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005163 Rev. C
06/28/11
Page 6