Technical Specification
100
95
90
85
80
75
70
16 Vin
65
28 Vin
40 Vin
60
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
14
12
10
8
6
4
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
2
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
25
40
55
70
85
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from pin 3 to pin 1 (nominal input voltage).
MCOTS-C-28-15-HP
Output: 15V
Current: 13A
26
24
22
20
18
16
14
12
10
8
6
16 Vin
4
28 Vin
2
40 Vin
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Load Current (A)
Figure 2: Power dissipation at nominal output voltage vs. load current
for minimum, nominal, and maximum input voltage at 25°C.
14
12
10
8
6
4
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
2
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
25
40
55
70
85
Ambient Air Temperature (°C)
Figure 4: Encased converter (with 1/4” heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from pin 3 to pin 1 (nominal input voltage).
Figure 5: Output voltage response to step-change in load current (50%-75%-
50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum
capacitors. Ch 1: Vout (1V/div), Ch 2: Iout (5A/div).
Figure 6: Output voltage response to step-change in input voltage
(250 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout
(1V/div), Ch 2: Vin (20V/div).
Product # MCOTS-C-28-15-HP Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005280 Rev. 1
06/16/09
Page 5