English
Language : 

PQ60050EML10 Datasheet, PDF (4/13 Pages) SynQor Worldwide Headquarters – 10 Amp, No Heatsink, Isolated DC/DC Converter
Technical Specification
Eighth
Brick
48Vin 5.0Vout 10A
ELECTRICAL CHARACTERISTICS (Continued)
Parameter P
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control (Option P)
Off-State Voltage
On-State Voltage
ON/OFF Control (Option N)
Off-State Voltage
On-State Voltage
ON/OFF Control (Either Option)
Pull-Up Voltage
Pull-Up Resistance
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia)
Calculated MTBF (MIL-217)
Demonstrated MTBF
Min.
230
-2
2.4
2.4
-2
-10
117
Typ.
260
Vin/6.5
40
122
125
10
2.4
1.4
TBD
Max. Units Notes & Conditions
290
kHz
0.8
V
18
V
18
V
0.8
V
Figures A, B
9.2
V
kΩ
+10
% Measured across Pins 8 & 4; Figure C
+10
% Measured across Pins 8 & 4
127
% Over full temp range; % of nominal Vout
°C Average PCB Temperature
°C
106 Hrs.
106 Hrs.
106 Hrs.
TMFRieI-LNl-dHWDdBTe-K0m-02o01n37s3Ft;2ra;8t08e%0d%MlolaoTdaB,dF,330000LLFFMM,,4400ooCCTTaa
STANDARDS COMPLIANCE
Parameter P
STANDARDS COMPLIANCE
UL/cUL 60950
EN60950
72/23/EEC
93/68/EEC
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
GR-1089-CORE
Telcordia (Bellcore) GR-513
Notes
File # E194341, Basic insulation & pollution degree 2
Certified by TUV
test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8kV - NP, 15kV air - NP
Section 7 - electrical safety, Section 9 - bonding/grounding
• An external input fuse must always be used to meet these safety requirements
QUALIFICATION TESTING
Parameter P
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
# Units Test Conditions
32
5
5
10
5
5
5
15 pins
95% rated Vin and load, units at derating point, 1000 hours
10-55Hz sweep, 0.060” total excursion,1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40°C to 100°C, unit temp. ramp 15°C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10°C to Tmax+10°C, 5°C steps, Vin = min to max, 0-105% load
85°C, 85% RH, 1000 hours, 2 minutes on and 6 hours off
MIL-STD-883, method 2003
• Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply
robust, reliable product. Contact factory for more information about Proof of Design and Proof of Manufacturing processes.
OPTIONS
SynQor provides various options for Enable Logic and Pin Length
for this family of DC/DC converters. Please consult the last page
of this specification sheet for information on available options.
PATENTS
SynQor is protected under various patents, including but not lim-
ited to U.S. Patent # 5,999,417.
Product # PQ60050EML10
Phone 1-888-567-9596
Doc.# 005-2EM650E Rev. A
5/22/03
Page 4