Technical Specification
Input: 35-75 V
Output: 48 V
Current: 3 A (144W)
Package: Quarter-brick
PQ60480QTA03 ELECTRICAL CHARACTERISTICS
TA=25°C, airflow rate=300 LFM, Vin=48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C ambient tem-
perature with appropriate power derating. Specifications subject to change without notice.
Parameter
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Non-Operating
Operating
Operating Transient Protection
Isolation Voltage (input to output)
Operating Temperature
Storage Temperature
Voltage at ON/OFF input pin
INPUT CHARACTERISTICS
Operating Input Voltage Range
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Voltage Hysteresis
Maximum Input Current
No-Load Input Current
Disabled Input Current
Inrush Current Transient Rating
Response to Input Transient
Input Reflected Ripple Current
Input Terminal Ripple Current
Recommended Input Fuse
Input Filter Component Values (L\C)
Recommended External Input Capacitance
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line1
Over Load1
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise2
Peak-to-Peak
RMS
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
DYNAMIC CHARACTERISTICS
Input Voltage Ripple Rejection
Output Voltage during Load Current Transient
For a Step Change in Output Current (0.1A/µs)
Settling Time
Turn-On Transient
Turn-On Time
Start-Up Inhibit Time
Output Voltage Overshoot
EFFICIENCY
100% Load
50% Load
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature
Board Temperature
Transformer Temperature
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
Isolation Resistance
Isolation Capacitance3
Min.
Typ. Max. Units Notes & Conditions
-40
-55
-2
35
31.5
28.7
2.5
47.4
46.9
0
3.5
0.1
0
230
48
32.5
29.5
3.5
120
2
1
13
40
3.3\6.6
47
48.00
+0.02\10
+0.02\10
+288
12
5
3.8
19
0.3
30
20
2
500
33
250
0
92
92
2000
30
470
100
80
100
2000
100
125
18
75
34.0
31.2
4.5
5.1
150
5
0.01
20
48.6
+0.1\48
+0.1\48
+400
49.1
150
60
3
4.4
0.8
55
688
270
125
125
125
V
Continuous
V
Continuous
V
100ms transient, square wave
V
Basic insulation, Pollution Degree 2
°C
°C
V
V
100V transient for 100ms
V
V
V
A
mA
mA
A2s
V
mA
mA
A
µH\µF
µF
100% Load, 35 Vin, trimmed up 5%
1000V/ms input transient
P-P thru 10µH inductor; Figures 13 & 15
RMS; Figures 13 & 14
Fast blow external fuse recommended
Internal values; Figure E (Lin\C2)
Typical ESR 0.1-0.2W; Figure 13
V
%\mV
%\mV
mV
V
mV
mV
A
A
V
A
mA
µF
Over sample, line, load, temperature & life
500MHz bandwidth; Figures 13 & 16
Full Load; Figures 13 & 16
Full Load; Figures 13 & 16
Subject to thermal derating; Figures 5 - 8
Output Voltage 10% Low
Negative current drawn from output source
Negative current drawn from output source
48Vout at 3A Resistive Load
dB 120 Hz; Figure 20
V
50% to 75% to 50% Iout max
µs
To within 1% Vout nom
ms Full load, ON/OFF to Vout=90% nom.; Figures 9 - 10
ms -40°C to +125°C; Figure E
%
688 µF load capacitance, Iout = 0A
%
Figures 1 & 2
%
Figures 1 & 2
°C Package rated to 150°C
°C UL rated max operating temp 130°C
°C See Figures 5 - 8 for derating curves
V
MW
pF
Note 1: Line and load regulation is limited by duty cycle quantization and does not indicate a shift in the internal voltage reference.
Note 2: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com).