PQ60120HPA20 Datasheet, PDF (3/13 Pages) SynQor Worldwide Headquarters – Half-brick DC/DC Converter
Technical Specification
Input: 35-75 V
Output: 12 V
Current: 20 A
Package: Half-brick
PQ60120HPA20 ELECTRICAL CHARACTERISTICS
TA=25°C, airflow rate=300 LFM, Vin=48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C ambient
temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Non-Operating
Operating
Operating Transient Protection
Isolation Voltage (input to output)1
Operating Temperature
Storage Temperature
Voltage at ON/OFF input pin
INPUT CHARACTERISTICS
Operating Input Voltage Range
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Voltage Hysteresis
Maximum Input Current
No-Load Input Current
Disabled Input Current
Inrush Current Transient Rating
Response to Input Transient
Input Reflected Ripple Current
Input Terminal Ripple Current
Recommended Input Fuse
Input Filter Component Values (C1\L\C2)
Recommended External Input Capacitance
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise1
Peak-to-Peak
RMS
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
DYNAMIC CHARACTERISTICS
Input Voltage Ripple Rejection
Output Voltage during Load Current Transient
For a Step Change in Output Current (0.1A/µs)
For a Step Change in Output Current (5A/µs)
Settling Time
Turn-On Transient
Turn-On Time
Start-Up Inhibit Time
Output Voltage Overshoot
EFFICIENCY
100% Load
50% Load
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature
Board Temperature
Transformer Temperature
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)2
Isolation Resistance
Isolation Capacitance3
Min.
-40
-55
-2
35
31.5
29.5
2.2
11.88
11.75
0
22
0.1
0
16
180
Typ. Max. Units Notes & Conditions
100
80
100
2000
100
125
18
V continuous
V continuous
V 100ms transient, square wave
V Basic insulation level, Pollution degree 2
°C
°C
V
48
75
V
33.3
31.0
2.3
90
2
0.03
3.5
5
210
1\3\6.4
47
34.4
32.4
2.4
7.6
110
5
20
V
V
V
A 100% Load, 35 Vin
mA
mA
A2s
V 1000V/ms input transient
mA RMS thru 10µH inductor; Figures 13 & 15
mA RMS; Figures 13 & 14
A fast blow external fuse recommended
µF\µH\µF internal values, see Figure E
µF Typical ESR 0.1-0.2Ω, see Figure 13
12.00
12.12
+0.05 \ 6
+0.1 \ 12
+45
+0.1 \ 12
+0.2 \ 24
+90
12.33
50
15
23.5
7.5
0.4
10
100
30
20
25
1.0
50
10,000
V
%\mV
%\mV
mV
V
mV
mV
A
A
V
A
mA
µF
over sample, line, load, temperature & life
20MHz bandwidth; Figures 13 & 16
Full Load, see Figures 13 & 16
Full Load, see Figures 13 & 16
Subject to thermal derating; Figures 5-8
Output Voltage 10% Low; Figure 17
Negative current drawn from output
Negative current drawn from output
12Vout at 20A Resistive Load
70
dB 120 Hz; Fig. 20
650
mV 50% to 75% to 50% Iout max; Figure 11
650
mV 50% to 75% to 50% Iout max; Figure 12
400
µs to within 1% Vout nom
20
24
ms Full load, Vout=90% nom.; Figures 9 & 10
200
240
ms -40°C to +125°C; Figure A
0
% 10,000 µF load capacitance, Iout = 0A
92.5
93.5
% Figures 1 - 4
% Figures 1 - 4
125
°C Package rated to 150°C
125
°C UL rated max operating temp 130°C
125
°C See Figures 5 - 8 for derating curves
2000
V
30
MΩ
3300
pF
Note 1: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 2: For applications requiring 2,250V of isolation, order module with V option (see ordering information on last page of this datasheet).
Note 3: Higher values of isolation capacitance can be added external to the module.
Product # PQ60120HPA20
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2HP612K Rev. E
3/08/05
Page 3