English
Language : 

PQ60120EKX04 Datasheet, PDF (2/15 Pages) SynQor Worldwide Headquarters – Output voltage trim permits custom voltages and voltage margining
Technical
Specification
PQ60-EK Family
MECHANICAL DRAWING - OPEN FRAME - EKA & EKL (LOW PROFILE)
TOP
.600 [15.24 ]
.450 [11.43 ]
.300 [7.62 ]
.150 [3.81 ]
.900 [22.86 ]
8 765 4
SIDE
EKA SIDE
EKL SIDE
.410 .014
[10.41 0.35]
OVERALL HEIGHT
.145
[3.68 ]
.340 .014
[8.64 0.35]
OVERALL HEIGHT
.145
[3.68 ]
2.30
[58.4 ]
2.00
[50.8 ]
.14
[3.6 ]
1
23
.15 [3.8 ]
.300 [7.62 ]
.600 [15.24 ]
.121 .017
[3.07 0.43]
BOTTOMSIDE
CLEARANCE
0.051 .017
[1.3 0.43]
BOTTOMSIDE
CLEARANCE
NOTES
1) Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm)
diameter standoff shoulders.
2) Pins 4 and 8 are 0.062” (1.57 mm) diameter with 0.100" (2.54 mm)
diameter standoff shoulders.
3) Other pin extension lengths available. Recommended pin length is
0.03” (0.76mm) greater than the PCB thickness.
4) All Pins: Material - Copper Alloy- Finish (RoHS 6/6) - Matte Tin over
Nickel plate
5) Undimensioned components are shown for visual reference only.
6) All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x
+/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm)
7) Weight: 0.85 oz (24 g) typical
8) Workmanship: Meets or exceeds IPC-A-610C Class II
9) The flanged pins are designed to permit surface mount soldering
(allowing to avoid the wave soldering process) through the use of the
flanged pin-in-paste technique.
10) UL/TUV standards require a clearance greater than 0.04” (1.02mm)
between input and output for Basic insulation. This issue should be
considered if any copper traces are on the top side of the user’s
board. Note that the ferrite core shown at left above is considered
part of the input/primary circuit.
PIN DESIGNATIONS
Pin Name Function
1 Vin(+) Positive input voltage
TTL input to turn converter on
2 ON/OFF and off, referenced to Vin(–), with
internal pull up.
3 Vin(–) Negative input voltage
4 Vout(–) Negative output voltage
5 SENSE(–) Negative remote sense1
6 TRIM Output voltage trim2
7 SENSE(+) Positive remote sense3
8 Vout(+) Positive output voltage
Notes:
1) SENSE(–) should be connected to Vout(–)
either remotely or at the converter.
2) Leave TRIM pin open for nominal output voltage.
3) SENSE(+) should be connected to Vout(+)
either remotely or at the converter.
Product # PQ60120EKx04
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005190 Rev. A
07/13/09