English
Language : 

MQFL-28-12D Datasheet, PDF (15/18 Pages) SynQor Worldwide Headquarters – HIIGH RELLIIABIILLIITTY DC/DC CONVERTTER
Technical Specification
MQFL-28-12D
Output: ±12 V
Current: 10 A Total
CONSTRUCTION AND ENVIRONMENTAL STRESS SCREENING OPTIONS
Screening
Consistent with
B-Grade
MIL-STD-883F (-40oC to +85oC)
C-Grade
(-40oC to +100oC)
Internal Visual
*
Yes
Yes
Temperature Cycle
Constant
Acceleration
Burn-in
Final Electrical Test
Mechanical Seal,
Thermal, and
Coating Process
External Visual
Construction
Process
Method 1010
Method 2001
(Y1 Direction)
Method 1015
Load Cycled
•10s period
•2s @ 100% Load
•8s @ 0% Load
Method 5005
(Group A)
2009
No
No
No
No
12 Hrs @ +100oC 24 Hrs @ +125oC
+25oC
+25oC
Anodized Package
Full QorSeal
*
Ruggedized
*
QorSeal
* Per IPC-A-610 (Rev. D) Class 3
ES-Grade
(-55oC to +125oC)
(Element Evaluation)
Yes
Condition B
(-55oC to +125oC)
500g
96 Hrs @ +125oC
-45, +25, +100oC
Full QorSeal
Yes
QorSeal
HB-Grade
(-55oC to +125oC)
(Element Evaluation)
Yes
Condition C
(-65oC to +150oC)
Condition A
(5000g)
160 Hrs @ +125oC
-55, +25, +125oC
Full QorSeal
Yes
QorSeal
MilQor converters and filters are offered in four variations of construction technique and environmental stress screening options. The
three highest grades, C, ES, and HB, all use SynQor’s proprietary QorSeal™ Hi-Rel assembly process that includes a Parylene-C coat-
ing of the circuit, a high performance thermal compound filler, and a nickel barrier gold plated aluminum case. The B-grade version
uses a ruggedized assembly process that includes a medium performance thermal compound filler and a black anodized aluminum
case†. Each successively higher grade has more stringent mechanical and electrical testing, as well as a longer burn-in cycle. The ES-
and HB-Grades are also constructed of components that have been procured through an element evaluation process that pre-qualifies
each new batch of devices.
† Note: Since the surface of the black anodized case is not guaranteed to be electrically conductive, a star washer or similar device
should be used to cut through the surface oxide if electrical connection to the case is desired.
Product # MQFL-28-12D
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2MQ120D Rev. A 10/23/07