PQ60050EKX10 Datasheet, PDF (14/15 Pages) SynQor Worldwide Headquarters – TUV certified to EN60950-1
Technical Specification
Input: 35-75V
Output: 5V
Current: 10A
Part No.: PQ60050EKx10
Figure F shows three turn-on scenarios, where a Startup Inhibit
Period is initiated at t0, t1, and t2:
Before time t0, when the input voltage is below the UVL threshold,
the unit is disabled by the Input Under-Voltage Lockout feature.
When the input voltage rises above the UVL threshold, the
Input Under-Voltage Lockout is released, and a Startup Inhibit
Period is initiated. At the end of this delay, the ON/OFF pin is
evaluated, and since it is active, the unit turns on.
At time t1, the unit is disabled by the ON/OFF pin, and it cannot
be enabled again until the Startup Inhibit Period has elapsed.
When the ON/OFF pin goes high after t2, the Startup Inhibit
Period has elapsed, and the output turns on within the typical
Turn-On Time.
Vin
Under-Voltage
Lockout
Turn-On
Threshold
ON/OFF
(pos logic)
ON
OFF ON
OFF
Vout
10ms
(typical start-up
inhibit period)
200ms
200ms
t0
t1
t2
Figure F: Startup Inhibit Period (turn-on time not to scale)
ON
2145ms
(typical turn on time)
t
Product # PQ60050EKx10
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005191 Rev. A
07/13/09
Page 14