English
Language : 

PQ60033ETL30 Datasheet, PDF (12/13 Pages) SynQor Worldwide Headquarters – Eighth-brick DC/DC Converter
Technical Specification
Input: 35-75 V
Output: 3.3 V
Current: 30 A
Package: Eighth-brick
At time t1, the input voltage falls below the Input Under-Voltage
Lockout threshold. This disables the unit and initiates a Restart
Inhibit Period. During the Restart Inhibit Period, if the input volt-
age again exceeds the UVLO threshold, the unit cannot be
enabled again until the Restart Inhibit Period has elapsed. Once
this occurs, the output turns on with the Typical Turn-On Time.
At time t2, the ON/OFF pin disables the unit and initiates a
Restart Inhibit Period. During the Restart Inhibit Period, if the
ON/OFF pin is again activated, the unit cannot be enabled
again until the Restart Inhibit Period has elapsed. Once this
occurs, the output turns on with the Typical Turn-On Time.
When the ON/OFF pin goes high after t3, and the Restart Inhibit
Period has elapsed, the output turns on approximately 1.6ms
after the ON/OFF pin is activated, with the Typical Turn-On Time.
If the Under-Voltage Lockout threshold has not been satisfied at
the end of either Inhibit Period, the unit will remain disabled until
the input voltage exceeds the UVLO threshold. Once this occurs,
the output turns on with the Typical Turn-On Time.
If the ON/OFF pin is activated after either Inhibit Period has
elapsed, the output will turn on approximately 1.6ms after the
ON/OFF pin is activated, with the Typical Turn-On Time.
RoHS Compliance: The EU led RoHS (Restriction of Hazardous
Substances) Directive bans the use of Lead, Cadmium,
Hexavalent Chromium, Mercury, Polybrominated Biphenyls
(PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical
and Electronic Equipment. This SynQor product is available as
6/6 RoHS compliant. For more information please refer to
SynQor’s RoHS addendum available at our RoHS Compliance /
Lead Free Initiative web page or e-mail us at rohs@synqor.com.
Vin
Under-Voltage
Lockout Turn-On
Threshold
ON/OFF
(pos logic)
ON
Vout
10ms
(typical start-up
inhibit period)
200ms
OFF ON
(typical restart
inhibit period)
200ms
t0
t1
t2
Figure F: Startup Inhibit Period (turn-on time not to scale)
OFF
200ms
t3
ON
13.5ms
(typical turn on time)
t
Product # PQ60033ETL30
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2ET633F Rev. A
06/01/06