NQ16W50SKA10 Datasheet, PDF (12/13 Pages) SynQor Worldwide Headquarters – SMT Surface Mount
Technical Specification
Input: 6.0 - 16.0V
Outputs: 0.75 - 5.0V
Current: 10A
Package: SMT
Reflow Soldering Guidelines: Figure J
shows a typical reflow profile for a eutectic sol-
Maximum Temperature (+210-260oC)
der process. Due to variations in customer
applications, materials and processes, it is not
feasible for SynQor to recommend a specific
Eutectic Solder Melting Point (+183oC)
reflow profile. The customer should use this pro-
file as a guideline only. Since the NiQor sur-
(+150-155oC)
face mount modules have a larger thermal mass
and lower thermal resistance than standard
SMT components, it may be necessary to opti-
Pre-heat
Soak
Reflow
Cool Down
mize the solder reflow profile based on limita-
tions of the other components on the customer
board. Sufficient reflow time must be allowed to
• < 2.5oC/sec
• 0.5-0.6oC/sec
• 60 to 90 sec.,
typ., 2 min max
• 1.3-1.6oC/sec
• 30 to 60 sec., typ.,
90 sec max
fuse the plating on the connection to ensure a
reliable solder joint. The solder reflow profile
should be confirmed by accurately measuring
2 to 4 min.
the SMT interconnect leads. Maximum case
temperature of 260°C (exposure for 5 seconds Figure J: Typical Eutectic (96.5Sn/3.0Ag/0.5Cu) Solder Profile
or less) is not exceeded for the NiQor units.
Moisture Sensitivity: The NiQor surface mount modules have
an MSL rating 1 per IPC/JEDEC J-STD-033A.
RoHS Compliance: The EU led RoHS (Restriction of
Hazardous Substances) Directive bans the use of Lead,
Cadmium, Hexavalent Chromium, Mercury, Polybrominated
Cleaning and Drying: When possible, a no-clean solder Biphenyls (PBB), and Polybrominated Diphenyl Ether (PBDE) in
paste system should be used to solder the NiQor SMT units to Electrical and Electronic Equipment. This SynQor product is 6/6
their application board. The modules are suitable for aqueous RoHS compliant. For more information please refer to SynQor’s
washing, however, the user must ensure sufficient drying to RoHS addendum available at our RoHS Compliance / Lead Free
remove all water from the converter before powering up. Initiative web page or e-mail us at rohs@synqor.com.
Inadequate cleaning and drying can affect the reliability of the
converter and the testing of the final assembly.
Product # NQ16W50SKA10
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-NS15W10 Rev. A 11/26/07
Page 12