PQ60120QTA12 Datasheet, PDF (11/13 Pages) SynQor Worldwide Headquarters – Quarter-brick DC/DC Converter
Technical Specification
amount of the Over-Temperature Shutdown Restart Hysteresis
value.
APPLICATION CONSIDERATIONS
Input System Instability: This condition can occur because
any DC/DC converter appears incrementally as a negative
resistance load. A detailed application note titled “Input
System Instability” is available on the SynQor web site
(www.synqor.com) which provides an understanding of why
this instability arises, and shows the preferred solution for cor-
recting it.
Application Circuits: Figure D below provides a typical cir-
cuit diagram which details the input filtering and voltage trim-
ming.
Input Filtering and External Capacitance: Figure E below
provides a diagram showing the internal input filter components.
This filter dramatically reduces input terminal ripple current,
which otherwise could exceed the rating of an external elec-
trolytic input capacitor. The recommended external input capac-
itance is specified in the “Input Characterisitcs” section. More
detailed information is available in the application note titled
“EMI Characteristics” on the SynQor website.
Input: 35-75 V
Output: 12 V
Current: 12 A
Package: Quarter-brick
Vin(+)
Vout(+)
Electrolytic
Vsense(+)
Vin
External
Input
Capacitor
47µF
ON/OFF
Rtrim-up
Trim
or
Filter
Vsense(_)
Rtrim-down Cload
Iload
Vin(_)
Vout(_)
Figure D: Typical application circuit (negative logic unit, permanently enabled).
Vin(+)
L
C
Vin(_)
Figure E: Internal Input Filter Diagram (component values listed on page 3).
Product # PQ60120QTA12
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2QT612C Rev. A 10/4/04
Page 11