PQ60012QPA60 Datasheet, PDF (1/13 Pages) SynQor Worldwide Headquarters – Quarter-brick DC/DC Converter | |||
|
Technical
Specification
PQ60012QPA60
48Vin 1.2Vout 60Amp 2000Vdc Quarter-brick
Input
Output
Current
Isolation
DC/DC Converter
The PQ60012QPA60 PowerQor® Peta quarter-brick con-
verter is a next-generation, board-mountable, isolated, fixed
switching frequency DC/DC converter that uses synchronous
rectification to achieve extremely high conversion efficiency.
The power dissipated by the converter is so low that a
heatsink is not required, which saves cost, weight, height,
and application effort. All of the power and control compo-
nents are mounted to the multi-layer PCB substrate with high-
yield surface mount technology. Since the PowerQor con-
verter has no explicit thermal interfaces, it is extremely reli-
able. The Peta series offers industry leading output currents for
any standard quarter-brick module. RoHS Compliant (see
page 12).
Operational Features
⢠Ultra-high efficiency, 87% half load, 84% full load
⢠Delivers up to 60 amps of output current with minimal
derating - no heatsink required
⢠Wide input voltage range: 36V â 75V, with 100V
100ms input voltage transient capability
⢠Fixed frequency switching provides predictable EMI
performance
⢠No minimum load requirement means no preload
resistors required
Mechanical Features
⢠Industry standard quarter-brick pin-out configuration
⢠Industry standard size: 1.45â x 2.3â (36.8x58.4mm)
⢠Total height less than 0.45â (11.4mm), permits better
airflow and smaller card pitch
⢠Total weight: 1.5 oz. (42 grams)
⢠Flanged pins designed to permit surface mount solder-
ing (avoid wave solder) using FPiP technique
Control Features
⢠On/Off control referenced to input side (positive and
negative logic options are available)
⢠Remote sense for the output voltage compensates for
output distribution drops
⢠Output voltage trim permits custom voltages and volt-
age margining
PQ60012QPA60 Module
Protection Features
⢠Input under-voltage lockout disables converter at low
input voltage conditions
⢠Output current limit and short circuit protection protects
converter and load from damage and consequent haz-
ardous conditions
⢠Active back bias limit prevents damage to converter
from external load induced pre-bias
⢠Output over-voltage protection protects load from dam-
aging voltages
⢠Thermal shutdown protects converter from abnormal
environmental conditions
Safety Features
⢠2000V, 30 MW input-to-output isolation provides
input/output ground separation
⢠UL/cUL 60950-1 recognized (US & Canada), basic
insulation rating
⢠TUV certified to EN60950-1
⢠Meets 72/23/EEC and 93/68/EEC directives which
facilitates CE Marking in userâs end product
⢠Board and plastic components meet UL94V-0 flamma-
bility requirements
Product # PQ60012QPA60
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2QP621F Rev. C
3/23/07
Page 1
|
▷ |