English
Language : 

PFCU390QPX04 Datasheet, PDF (1/16 Pages) SynQor Worldwide Headquarters – Internal inrush current limit
PFCU390QPx04
Power Factor Correction
Quarter-Brick
Power Factor Correction Module
85-264Vrms
Input Voltage
47 - 63Hz / 360 - 800Hz
Input Frequency
390Vdc
Output Voltage
350W
Output Power
≥0.99
Power Factor
Up to 96%
Full Load Efficiency
The PFCQor® Power Factor Correction module
is an essential building block of an AC-DC
power supply. Used in conjunction with a hold-
up capacitor, SynQor’s DC-DC converters and
SynQor’s AC line filter, the PFCQor will draw a
nearly perfect sinusoidal current (PF>0.99) from
a single phase AC input. The module is supplied
completely encased to provide protection from
the harsh environments seen in many industrial
and transportation environments.
PPF4OC87WU5-3E-269R6304HFQAVzPCr/CmT03Os46R3S09CR-0OS8VR-0Gd0RcHE3zC5T0IOWN
Operational Features
• Input voltage range: 85-264Vrms
• Universal input frequency range: 47 - 63Hz / 360 - 800Hz
• 350W output power
• ≥0.99 Power Factor
• High efficiency: >95% (230Vrms)
• Internal inrush current limit
• Auxiliary 10V bias supply
Mechanical Features
• Industry standard quarter-brick pin-out
• Size: 1.54” x 2.39” x 0.50” (39.0 x 60.6 x 12.7 mm)
• Total weight: 3.07 oz. (87 g)
• Flanged baseplate version available
Safety Features
• Input/Output to baseplate isolation 2150Vdc
• UL 60950-1:2007
• CAN/CSA-C22.2 No. 60950-1:2007
• EN60950-1/A12:2011
• CE Marked
Product # PFCU390QPx04
Phone 1-888-567-9596
Control Features
• PFC Enable
• Load Enable (also: Power Out Good signal)
Protection Features
• Input current limit and auto-recovery short circuit protection
• Auto-recovery input under/over-voltage protection
• Auto-recovery output over-voltage protection
• Auto-recovery thermal shutdown
Compliance Features
(With SynQor AC Line Filter)
• EN55011 and EN55022, FCC
• EN61000-3-2
• EN61000-3-3
• EN61000-4-4/5/6/11
Contents
Page No.
Technical Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Standards & Qualification Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Mechanical Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
www.SynQor.com
Doc.# 005-0006788 Rev. B 03/31/2016
Page 1