English
Language : 

PFCU390HPX07 Datasheet, PDF (1/17 Pages) SynQor Worldwide Headquarters – Up to 700W output power
PFCU390HPx07
Power Factor Correction
Half-brick
Power Factor Correction Module
85-264Vrms* 47 - 63Hz / 360 - 800Hz
Input Voltage
Input Frequency
390Vdc
Output Voltage
700W
Output Power
≥0.99
Power Factor
Up to 96%
Full Load Efficiency
The PFCQor® Power Factor Correction module
is an essential building block of an AC-DC
power supply. Used in conjunction with a
hold-up capacitor, SynQor’s high efficiency DC-
DC converters and SynQor’s AC line filter, the
PFCQor will draw a nearly perfect sinusoidal
current (PF>0.99) from a single phase AC input.
The PFCQor is capable of being paralleled for
higher power levels. The module is supplied
completely encased to provide protection from
the harsh environments seen in many industrial
and transportation environments.
PPF4OC17WU0-3E069R-2304HFHA0zPVC/CrT0m3O76RsS03CR-9OS80R-0GV0RdHEczC7T0IO0NW
* The label shows a narrower input voltage range to be consisitent with labeling
requirements of IEC60950-1, Section 1.7
Operational Features
• Universal input voltage range: 85-264Vrms
• Universal input frequency range: 45 - 65Hz / 360 - 800Hz
• Up to 700W output power
• ≥0.99 Power Factor
• High efficiency: >96% (230Vrms)
>94% (115Vrms)
• Internal inrush current limit
• Auxiliary 10V bias supply
• Can be paralleled with current sharing
• Compatible with SynQor DC-DC converters & AC line filters
Mechanical Features
• Industry standard half-brick pin-out
• Size: 2.386” x 2.486” x 0.512” (60.6 x 63.1 x 13.0 mm)
• Total weight: 4.9 oz (139 g)
• Flanged baseplate version available
Safety Features
• Input/Output to baseplate isolation 2150Vdc
• UL 60950-1:2007
• CAN/CSA-C22.2 No. 60950-1:2007
• EN60950-1/A12:2011
• CE Marked
Control Features
• PFC Enable
• Load Enable (also: Power Out Good signal)
• AC Power Good Signal
• Clock synchronization
• Output current monitor / Active current sharing
Protection Features
• Input current limit and auto-recovery short circuit protection
• Auto-recovery input under/over-voltage protection
• Auto-recovery output over-voltage protection
• Auto-recovery thermal shutdown
Compliance Features
(With SynQor AC Line Filter)
• EN55011 and EN55022, FCC
• EN61000-3-2
• EN61000-3-3
• EN61000-4-4/5/6/11
Contents
Page No.
Technical Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Standards & Qualification Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Mechanical Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Product # PFCU390HPx07
Phone 1-888-567-9596
www.SynQor.com
Doc.# 005-0006254 Rev. E 04/07/2016
Page 1