English
Language : 

MPFC-U-390-HP Datasheet, PDF (1/18 Pages) SynQor Worldwide Headquarters – Auxiliary 10V bias supply
MPFC-U-390-HP
Power Factor Correction
Half-brick
Military Power Factor Correction Module
85-264Vrms
Input Voltage
47 - 63Hz / 360 - 800Hz 390Vdc
Input Frequency
Output Voltage
700W
Output Power
≥0.99
Power Factor
Up to 95%
Full Load Efficiency
The MPFCQor Military Power Factor Correction
module is an essential building block of an AC-DC
power supply. Used in conjunction with a hold-up
capacitor, SynQor’s MCOTS DC-DC converters and
SynQor’s MCOTS AC line filter, the MPFCQor will draw
a nearly perfect sinusoidal current (PF>0.99) from
a single phase AC input. A version capable of being
paralleled for higher power levels is available. The
module is supplied completely encased to provide
protection from the harsh environments seen in
many industrial and transportation environments.
MMP4IFL87CI5T---A6U2R3-63YH49PzV0Or/-mWH3sPE63-R0N9F--0MA8VC0dT0cOHR7z0C0OWRRECTION
Operational Features
• Input voltage range: 85-264Vrms
• Universal input frequency range: 47 - 63Hz / 360 - 800Hz
• 700W output power
• ≥0.99 Power Factor
• High efficiency: >95% (230Vrms)
• Internal inrush current limit
• Auxiliary 10V bias supply
• Can be paralleled with current sharing
• Compatible with SynQor’s MCOTS DC-DC converters
and SynQor’s MCOTS AC line filters
Mechanical Features
• Industry standard half-brick pin-out
• Size: 2.386” x 2.486” x 0.512” (60.6 x 63.1 x 13.0 mm)
• Total weight: 4.9 oz (139 g)
• Flanged baseplate version available
Safety Features
• Input/Output to baseplate isolation 2150Vdc
• UL 60950-1/R:2011-12
• CAN/CSA-C22.2 No. 60950-1/A1:2011
• EN60950-1/A2:2013
• CE Marked
Designed and manufactured in the USA
Control Features
• PFC Enable
• Load Enable (also: Power Out Good signal)
• AC Power Good Signal
• Clock synchronization
• Output current monitor / Active current sharing
Protection Features
• Input current limit and auto-recovery short circuit protection
• Auto-recovery input under/over-voltage protection
• Auto-recovery output over-voltage protection
• Auto-recovery thermal shutdown
Compliance Features
Designed to meet these standards when used with
SynQor MACF Filters & MCOTS DC-DC Converters.
• MIL-STD-461(A-F)
• MIL-STD-1399
• MIL-STD-704-2, -704-4, & -704-6* (see 704 app section)
Contents
Page No.
Typical Application............................................................................2
Standards & Qualification Testing.......................................................7
Application Section...........................................................................8
Encased Mechanical........................................................................16
Encased Mechanical with Flange......................................................17
Ordering Information......................................................................18
Product MPFC-U-390-HP
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0006642 Rev. C
04/07/2016
Page 1