English
Language : 

LFSW300600-20 Datasheet, PDF (1/7 Pages) SYNERGY MICROWAVE CORPORATION – INTELLIGENT INTERACTIVE SYNTHESIZER
INTELLIGENT INTERACTIVE SYNTHESIZER
SURFACE MOUNT MODEL: LFSW300600-20
wide bandwidth
3000 - 6000 MHz
FEATURES:
► Exceptionally Low Phase Noise
► Interactive Communication
► Standard Programming Interface
► Ultra Wide Tuning Range
► Lead Free - RoHS Compliant
► Patent Pending REL-PRO® Technology
► Small Size, Surface Mount
► Buffered Output
Phase Noise
-60
-70
-80
-90
-100
-110
-120
-130
-140
-150
-160
100
1000
10000
100000
1000000 10000000 100000000
Offset Frequency (Hz)
3000 MHz 4500 MHz 6000 MHz
SPECIFICATIONS (Rev. A 05/01/08)
Frequency
Step Size
Reference Input Frequency
Reference Input Voltage
3000 - 6000 MHz
200 kHz
100 MHz *
1 V p-p to 3.3 V p-p
Bias Voltage
Vcc
Digital
VCO
Converter
V (Vdc)
+5
+5
+5
I (mA Max.)
35
45
65
Output Power
Spurious Suppression
Harmonic Suppression
Settling Time
Output Impedance
+5 dBm (Min.)
60 dB (Typ.)
15 dB (Typ.)
15 mSec (Typ.) **
50 Ohms (Nom.)
Typical Phase Noise
Offset
@ 1 kHz
@ 10 kHz
@ 100 kHz
Phase Noise
-75 dbc/Hz
-73 dbc/Hz
-98 dbc/Hz
Operating Temperature Range -20 to +70 °C
Programming
See Application Note: AN7100
* Reference input frequency is programmable in multiples of the step size,
from 10 MHz to 150 MHz. 100 MHz is the default setting.
** From the rising edge of LE to stable lock detect
Absolute Maximum Ratings
Storage Temp. Range
Bias Voltage (Digital)
Bias Voltage (VCO)
Bias Voltage (Converter)
DC Voltage Applied to RF Out
-55 to +125 ºC
+5.25 V
+5.5 V
+8 V
±25 V
Package #
197LF
Pin 5 - RF out
Pin 7 - Lock Detect Out *
Pin 9 - Data In
Pin 10 - Error Flag
Pin 11 - Clock In
Pin 13 - VCO (On/Off)****
Pin 16 - Reset **
Pin-Out
Pin 19 - Latch Enable In
Pin 21 - Ref. In
Pin 23 - Vcc (Digital)
Pin 24 - Vtune (Output)
Pin 25 - Vcc (VCO)
Pin 26 - Vout (Converter) ***
Pin 27 - Vcc (Tune) ***
Pin 28 - Vcc (Converter)
Pin 8,12,14,15,17 - NC
All Others - Ground
NC - No Connection
* High when locked (source/sink 500 uA)
** A low on this input will reset the internal controller. Leave unconnected for
normal operation.
*** Connect externally. Bypassed with a 10uF 35V tantalum capacitor.
**** NC if unused.