English
Language : 

HV220 Datasheet, PDF (3/12 Pages) Supertex, Inc – Low Charge Injection 8-Channel High Voltage Analog Switches
Truth Table
HV220/HV20220/HV20320
D0 D1 D2 D3 D4 D5 D6 D7 LE CL SW0 SW1 SW2 SW3 SW4 SW5 SW6 SW7
L
L L OFF
H
L L ON
L
LL
OFF
H
LL
ON
L
LL
OFF
H
L
LL
LL
ON
OFF
H
LL
ON
L
LL
OFF
H
LL
ON
L
LL
OFF
H
LL
ON
L
LL
OFF
H
LL
ON
L LL
OFF
HLL
ON
X XXX X XXX H L
HOLD PREVIOUS STATE
X X X X X X X X X H OFF OFF OFF OFF OFF OFF OFF OFF
Notes:
1. The eight switches operate independently.
2. Serial data is clocked in on the L to H transition CLK.
3. The switches go to a state retaining their present condition at the rising edge of LE. When LE is low the shift register
data flows through the latch.
4. DOUT is high when data in shift register 7 is high.
5. Shift register clocking has no effect on the switch states if LE is H.
6. The clear input overrides all other inputs.
B021706
3