English
Language : 

HV209 Datasheet, PDF (1/8 Pages) Supertex, Inc – 12-Channel High Voltage Analog Switch
HV209
12-Channel High Voltage Analog Switch
Ordering Information
VPP – VNN
Package Options
48-pin TQFP
Die
200V
HV209FG
HV209X
Features
❏ HVCMOS technology for high performance
❏ Operating voltage of up to 200V
❏ Output On-resistance typically 22Ω
❏ Integrated bleed resistors on the outputs
❏ Very low quiescent power dissipation -10µA
❏ Low parasitic capacitances
❏ -58dB typical output off isolation at 5MHz
❏ 5.0V to 12V CMOS logic circuitry
❏ Excellent noise immunity
❏ Flexible high voltage supplies
General Description
The Supertex HV209 is a 200V low charge injection 12-
channel high voltage analog switch configured as 6 SPDT
analog switch intended for medical ultrasound applications.
Bleed resistors are integrated on the output switches to
eliminate charge built up on the piezo electric transducers.
The bleed resistors are at a nominal value of 35KΩ. Using
HVCMOS technology, this device combines high voltage
bilateral DMOS switches and low power CMOS logic to pro-
vide efficient control of high voltage analog signals. The
outputs are configured as single pole double throw analog
switches. Data is shifted into a 6-bit shift register using an
external clock. The LE latches the shift register data into the
individual switch latches. A logic high connects a switch
common YX to SWX. A logic low connects YX to SWX. A logic
hi in CL resets all switches to SWX simultaneously.
Absolute Maximum Ratings*
VDD Logic power supply voltage
VPP - VNN Supply voltage
VPP Positive high voltage supply
VNN Negative high voltage supply
Logic input voltages
VSIG Analog Signal Range
Peak analog signal current/channel
-0.5V to +15V
+220V
-0.5V to +200V
+0.5V to -200V
-0.5V to VDD +0.3V
VNN to VPP
3.0A
Storage temperature
-65°C to +150°C
Power dissipation
1.0W
* All voltages are referenced to ground. Absolute maximum ratings are those
values which damage to the device may occur. Functional operation under
these conditions is not implied. Continuous operation of the device at the
absolute rating level may affect device reliability.
11/12/01
Supertex Inc. does not recommend the use of its products in life support applications and will not knowingly sell its products for use in such applications unless it receives an adequate "products liability
indemnification insurance agreement." Supertex does not assume responsibility for use of devices described and limits its liability to the replacement of devices determined to be defective due to
workmanship. No responsibility is assumed for possible omissions or inaccuracies. Circuitry and specifications are subject to change without notice. For the latest product specifications, refer to the
Supertex website: http://www.supertex.com. For complete liability information on all Supertex prod1ucts, refer to the most current databook or to the Legal/Disclaimer page on the Supertex website.