HV111
Initial Release
Inrush Limiter/Circuit Breaker/Hotswap Controller IC
(No External Parts Required)
Features
❑ No External Parts Required
❑ On Board 80V, 2A MOSFET
❑ No Rsense Needed
❑ ±8.0V to ±80V Input Voltage Range
❑ Two Level Current Limiting
❍ 1.2A Initial Inrush Limit
❍ 2.0A Second Inrush Limit/Circuit Breaker Triggers
Servo Limit to 1.2A for T then shuts down
oc
❑ Fast Response Current Limit when Over Current or Step
Voltage at Input Supply (eg. Diode ‘OR’ing)
❑ UVLO/ENABLE & POR Supervisory Circuits
❑ Programmable UVLO
❑ Over Current Protection
❑ 9.0sec Auto Retry
❑ Built in Thermal Shutdown with Hysteresis
❑ 80V Open Drain PWRGD bar Flag
❑ Thermally Rugged DPAK5 Package
Applications
❑ Power Ethernet Systems
❑ Routers, Switches
❑ Chargers
❑ Security Peripherals & Cameras
❑ Automotive Protection
❑ Negative Supply Rail Breaking Applications
❑ Networking Line Cards
❑ Telecom Line Cards
Description
The HV111 is a complete power management solution for
switched or pluggable backplane applications up to 1.65A,
running from –8.0 to -80V, requiring no external components
or programming in many applications. The HV111 is not
limited to only negative input voltages. It can also be
used in +8.0 to +80V systems.
An internally programmed supervisor UVLO/ ENABLE may
be overridden with external resistors for custom settings.
Satisfying this supervisor will begin a POR phase to ensure
de-bouncing. Thereafter, a servo loop controls an internal
80V, 2A pass element to limit current. The circuit uses
internal mirrors to measure current, eliminating the need for
a sense resistor.
The HV111 includes two current modes: i) initial current limit
mode limits the current to 1.2A during turn on; ii) thereafter a
2A monitor circuit will re-trigger the servo mechanism back
to 1.2A limit if it is tripped. An on-board thermal supervisor
ensures that the device can never be damaged by over
current conditions.
Circuit breaker functionality is obtained through a either a
current limit timeout or a PWM current limiter for severe
faults. If the servo limits for more than 75ms then the part
will shut down the pass element, and initiate a 9sec timer
after which the turn on sequence will restart.
The HV111 is available in a thermally rugged DPAK-5
package which provides improved thermal resistance when
compared to SO-8 based solutions.
Typical Schematics and Waveforms
INRUSH
PWRGD*
DRAIN*
GND*
*Referred to –48V
7/24/03
Supertex Inc. does not recommend the use of its products in life support applications and will not knowingly sell its products for use in such applications unless it receives an adequate
"products liability indemnification insurance agreement." Supertex does not assume responsibility for use of devices described and limits its liability to the replacement of devices determined
to be defective due to workmanship. No responsibility is assumed for possible omissions or inaccuracies. Circuitry and specifications are subject to change without notice. For the latest
product specifications, refer to the Supertex website: http://www.supertex.com. For complete liability information on all Supertex products, refer to the most current databook or to the
Legal/Disclaimer page on the Supertex website.