English
Language : 

STM1066 Datasheet, PDF (8/20 Pages) STMicroelectronics – Smart voltage supervisor
Operation
2
Operation
STM1066
The STM1066 connects or disconnects the output OUT, from the VIN pin based on the
logical combination of the enable input (EN), the inhibit input (INH), and the supply voltage
level, VCC (see Table 2 or Figure 11 for more details).
2.1
Output, OUT
If the enable input is in a logic high state and inhibit input is in a logic low state, the output
will be connected to VIN input as VCC rises above the VTH+ voltage threshold. Otherwise, the
output is connected to ground GND. The output is current limited (see Table 5).
2.2
Enable input, EN
A Logic low on the enable input disconnects the output from VIN and disables the device,
which enters a standby mode with very low current consumption (see Table 5).
2.3
Inhibit input, INH
A logic high on the inhibit input disconnects the output from VIN.
Table 2. Truth table
VCC
EN(1)
INH
OUT
<VTH+ (rising edge)
x
<VTH- (falling edge)
x
L
x
connected to GND
x
connected to GND
x
x
H
connected to GND
>VTH+ (rising edge)
H
>VTH- (falling edge)
L
connected to VIN
1. Once the device is disabled by EN input, the VCC must be above VTH+ to reconnect output to VIN.
8/20