AN4007
Test board: design and evaluation
Table 3. VIPER37LE power supply: transformer characteristics
Manufacturer Magnetica
Values
Part number
1715.0038
Primary inductance
1.3 mH
Leakage inductance
Primary to secondary turn ratio
3% nom
16.2 ± 5%
Primary to auxiliary turn ratio
5.90 ± 5%
Insulation primary-secondary
AC 4 kV (1 s – 2 mA)
Figure 3. Dimensional drawing
1.1
Output voltage characteristics
The output voltage of the board is measured in different line and load conditions. Figure 4
shows the results: the output voltage variation range is a few tens of mV for all the tested
conditions.
All output voltages have been measured on the output connector of the board.
Doc ID 022455 Rev 2
7/33