English
Language : 

ALTAIR04-900 Datasheet, PDF (7/29 Pages) STMicroelectronics – Off-line all-primary-sensing switching regulator
ALTAIR04-900
4
Electrical characteristics
Electrical characteristics
(TJ = -25 to 125 °C, Vcc = 14 V; unless otherwise specified)
Table 4.
Symbol
Electrical characteristics
Parameter
Test condition
Min. Typ. Max. Unit
Power section
V(BR)DSS Drain-source breakdown
IDSS Off state drain current
RDS(on) Drain-source ON-state resistance
Coss Effective (energy-related) output capacitance
High-voltage start-up generator
ID< 100 µA; Tj = 25 °C
VDS = 850 V; Tj = 125 °C
(See Figure 4 and note)
Id=250 mA; Tj = 25 °C
Id=250 mA; Tj = 125 °C
(See Figure 3)
900
V
80 µA
16 19
W
38
VStart Min. Drain start voltage
Icharge Vcc startup charge current
VCCrestart Vcc restart voltage (Vcc falling)
Icharge < 100 µA
VDRAIN> VStart; Vcc < VccOn
Tj = 25 °C
VDRAIN> VStart; Vcc < VccOn
(1)
After protection tripping
40 50 60 V
4 5.5 7
mA
+/-10%
9.5 10.5 11.5
V
5
Supply voltage
Vcc Operating range
VccOn
VccOff
VZ
Turn-on threshold
Turn-off threshold
Zener voltage
Supply current
After turn-on
(1)
(1)
Icc = 20 mA
11.5
23 V
12 13 14 V
9 10 11 V
23 25 27 V
Iccstart-up Start-up current
Iq Quiescent current
Icc Operating supply current @ 50 kHz
Iq(fault) Fault quiescent current
(See Figure 5)
(See Figure 6)
(See Figure 7)
During hiccup and brownout
(See Figure 8)
200 300 µA
1 1.4 mA
1.4 1.7 mA
250 350 µA
Start-up timer
TSTART Start timer period
TRESTART Restart timer period during burst mode
Zero current detector
100 125 175 µs
400 500 700 µs
IZCDb Input bias current
VZCDH Upper clamp voltage
VZCD = 0.1 to 3 V
IZCD = 1 mA
0.1 1 µA
3.0 3.3 3.6 V
Doc ID 18211 Rev 2
7/29