English
Language : 

L99MM70XP Datasheet, PDF (60/68 Pages) STMicroelectronics – INH input for external CAN transceiver
SPI control and status registers
L99MM70XP
9.1.7 Status registers
Table 42. Status register 1
Status register 1 (11h)
Bit
Reset
state
Name
15
0
ECFDLS
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
ECV OUT OUT OUT OUT OUT5 OUT5 OUT4 OUT4 OUT3 OUT3 OUT2 OUT2 OUT1 OUT1
LS 9HS 8HS 7HS 6HS HS
LS HS LS HS LS HC LS HS LS
Table 43. Status register 1, bits
Bit name
Comment
ECFDLSOC
ECVLSOC
OUT9HSOC
OUT8HSOC
OUT7HSOC
OUT6HSOC
OUT5HSOC
OUT5LSOC
OUT4HSOC
OUT4LSOC
OUT3HSOC
Overcurrent diagnosis:
In case of an overcurrent event the corresponding status bit is set and the output driver is disabled.
If the overcurrent recovery enable bit is set, the output is automatically reactivated after a delay time
resulting in a PWM modulated current with a programmable duty cycle.
If the overcurrent recovery bit is not set, the microcontroller has to clear the overcurrent bit to
reactivate the output driver.
OUT3LSOC
OUT2HSOC
OUT2LSOC
OUT1HSOC
OUT1LSOC
60/68
Doc ID 022637 Rev 2