English
Language : 

HCF4510B Datasheet, PDF (6/12 Pages) STMicroelectronics – PRESETTABLE UP/DOWN COUNTERS
HCF4510B/4515B
DYNAMIC ELECTRICAL CHARACTERISTICS (Tamb = 25 oC, CL = 50 pF, RL = 200 KΩ,
typical temperaturecoefficent for all VDD values is 03 %/oC, all input rise and fall times= 20 ns)
Symb ol
P a ramet er
Test Conditions
Value
Un it
VDD Min. Typ. Max.
(V)
tPHL Propagation Delay Time Clock to Q Output
tPLH
5
200 400
10
100 200
ns
15
75 150
tPHL Propagation Delay Time Preset or Reset to
tPLH Q Output
5
210 420
10
105 210 ns
15
80 160
tPHL Propagation Delay Time Clock to Carry Out
tPLH
5
240 480
10
120 240 ns
15
90 180
tPHL Propagation Delay Time Carry In to Carry
tPLH Out
5
125 250
10
60 120
ns
15
50 100
tPHL Propagation Delay Time Preset or Reset to
tPLH Carry Out
5
320 640
10
160 320 ns
15
125 250
tTHL Transition Time
tTLH
5
100 200
10
50 100 ns
15
40 80
fMAX Max Clock Frequency
5
2
4
10
4
8
MHz
15
5.5
11
tW Clock Pulse Width
5
150
10
75
ns
15
60
Preset Enable or Reset Removal Time (1)
5
150
10
80
ns
15
60
tr, tf Clock Rise and Fall Time (2)
5
15
10
5
µs
15
5
tsetup Carry In Setup Time
5
130
10
60
ns
15
45
tsetup Up Down Setup Time
5
360
10 160
ns
15 110
tW Preset Enable or Reset Pulse Width
5
220
10 100
ns
15
75
(1) Timerequired after the falling edge of the reset or preset enable inuts before the rising edge ofthe clock will trigger the counter (similar to setup time).
(2) Ifmore than unit is cascated in the parallel clocked application, trCL should be made less than or equal to the sum of the fixed propagation delay at
15pF and the transition timeof the carry output driving stage ofthe estimated capacitive load.
6/12